Specifications

24 Installer Manual SATEL
LCD Keypad
You can add wireless devices in service mode, using the NEW DEVICE function (STRUCTURE
HARDWARE EXPANDERS SETTINGS ABAX - INTEGRA NEW DEVICE).
1. Start the NEW DEVICE function.
2. Enter the device 7-digit serial number and press the
key. The serial number can be
found on the electronics board or on the enclosure. Each ARF-100 radio signal level
tester has serial number 0000500. If a device with the entered serial number is already
registered, the keypad will not proceed to the next step of the procedure.
3. When the "Open device tamper" command is displayed:
power on the ACX-200 or ACX-201 expander,
turn on the ARF-100 tester,
insert the ASW-100 E / ASW-100 F wireless controller into 230 V AC socket,
violate (open) the tamper contact in case of the other devices.
If the serial number of device to be added is not consistent with that previously entered,
you will be informed about it by a suitable message. If this is the case, press the key
and then start the device adding procedure from the beginning.
4. The name and serial number of the new device will be displayed. Press the key 1 to
proceed to the next step of the procedure (press another key to terminate the new device
adding procedure).
5. A suitable message will inform you about the option, if any, whether the device will take
up one or two positions (channels) on the list of devices. Press the key 1 to select one
channel or press the key 2 to select two channels.
6. A list of system zones to which the device can be assigned will be displayed. Using the
and keys, select one of them and press the key (press the key to terminate the
new device adding procedure). If the device takes more than one position on the list of
devices, additional zones, following the selected one, will be automatically assigned to the
device.
7. A message will be displayed to inform you that the expander identification function has
been started.
8. After identification of the devices, the keypad will display a suggested name for the zone
to which the device is assigned. The name can be changed. The name will also be
assigned to the output, if the device is to be assigned to the output. Press the key to
save the new name. Press the key to terminate the name giving procedure (the zone
will then be given a name consisting of the name and serial number of the device). If the
device occupies more than one zone, this procedure is repeated for each zone.
DLOADX program
You can add wireless devices in the "Structure" window, "Hardware" tab, after clicking on the
„Wireless System”.
1. Click on the "New device" button. The "New device" window will open.
2. Enter in the appropriate field the 7-digit serial number of the device you want to add. The
serial number can be found on the electronics board or on the enclosure. Each ARF-100
radio signal level tester has serial number 0000500.
3. Depending on which device is to be added to the system:
power on the ACX-200 or ACX-201 expander,
turn on the ARF-100 tester,
insert the ASW-100 E / ASW-100 F wireless controller into 230 V AC socket,
violate (open) the tamper contact in case of the other devices.