Specifications

SATEL INTEGRA 128-WRL 23
zones
outputs
It.
list of devices
No
device
No
device
1 APD-100 detector
8
17 APD-100 detector 17 unused/unavailable
2 APD-100 detector 18 APD-100 detector 18 unused/unavailable
3 AMD-100 detector 19 AMD-100 detector 19 unused/unavailable
4 AMD-100 detector 20 AMD-100 detector 20 unused/unavailable
5 AMD-101 detector 21 AMD-101 detector 21 unused/unavailable
6 ^ 22 AMD-101 detector 22 unused/unavailable
7 23 unused/unavailable 23 unused/unavailable
8 ASP-105 siren 24 ASP-105 siren 24 ASP-105 siren
9 ^
8
25 ASP-105 siren 25 ASP-105 siren
10 26 unused/unavailable 26 unused/unavailable
11 27 unused/unavailable 27 unused/unavailable
12 28 unused/unavailable 28 unused/unavailable
13 29 unused/unavailable 29 unused/unavailable
14 30 unused/unavailable 30 unused/unavailable
15 31 unused/unavailable 31 unused/unavailable
16 32 unused/unavailable 32 unused/unavailable
Table 4. An example of how the wireless devices should not be registered. For devices taking
up 8 positions, the system must reserve 16 zones and 16 outputs.
zones outputs
It. list of devices No device No device
1 ASP-105 siren
8
17 ASP-105 siren 17 ASP-105 siren
2 ^ 18 ASP-105 siren 18 ASP-105 siren
3 APD-100 detector 19 APD-100 detector 19 unused/unavailable
4 APD-100 detector 20 APD-100 detector 20 unused/unavailable
5 AMD-100 detector 21 AMD-100 detector 21 unused/unavailable
6 AMD-100 detector 22 AMD-100 detector 22 unused/unavailable
7 AMD-101 detector 23 AMD-101 detector 23 unused/unavailable
8 ^ 24 AMD-101 detector 24 unused/unavailable
Table 5. An example of how to correctly register the wireless devices. For 8 devices, the
system has reserved 8 zones and 8 outputs.
Several ABAX systems can work within each other's range. Automatic synchronization with
the wireless systems already in use is always performed at the control panel start-up, and
after each operation of addition/removal of supported devices. The number of wireless
devices working within each other's range depends on the RESPONSE PERIOD (see:
PROGRAMMING manual) and can vary from 150 to 450. The higher the response frequency,
the lower the number of devices that can work within each other's range.
5.13.1 Adding new wireless devices
For some wireless devices, you can select whether the device will take up one or two
positions (channels) on the list of devices. Depending on the device, if one position is
selected:
AMD-102 only additional inputs (roller shutter and NC) will be supported;
ATD-100 you will be able to program only one temperature threshold;
AVD-100 only the vibration detector will be supported.