Specifications

20 Installer Manual SATEL
DLOADX program ("Structure" window "Hardware" tab "Keypads" branch
"Keypads identification" button).
3. Identification by the control panel of devices connected to the expander bus. The
identification can be performed by means of:
the keypad ([SERVICE CODE] SERVICE MODE STRUCTURE HARDWARE
IDENTIFICATION EXPANDERS ID.);
DLOADX program ("Structure" window "Hardware" tab "Expansion modules" branch
"Exp. modules identification" button).
The identification function must be run every time when a new device is connected to
the bus or the address of a device connected to the bus is changed.
Disconnecting the identified device from the communication bus will trigger a tamper
alarm.
Any attempt to replace the identified device with another one having the same address
will trigger a tamper alarm.
5.11 Emergency procedure of the control panel start-up
If the control panel fails to start properly, keypads are not supported, codes are not accepted
by the control panel etc., despite all connections having been made correctly, follow the steps
below:
1. Turn off the control panel power supply (first disconnect the AC power, and then the
battery).
2. Put a jumper on the RESET pins located on the control panel mainboard.
3. Turn on the control panel power supply (first connect the battery and then the AC power).
4. Wait about 10 seconds and remove the jumper from the pins. The control panel will enter
the service mode. The service mode menu will be displayed on the keypad with the
lowest address.
If a computer with the DLOADX program running is connected to the RS-232 port, the
service mode will not start (it will be possible to program the control panel locally from
the computer).
5. Restore the factory default settings using the CLEAR ALL function (RESTARTS CLEAR
ALL
).
6. Start the KEYPADS ADDR. function (STRUCTURE HARDWARE IDENTIFICATION KEYPADS
ADDR
.) and set individual addresses in the keypads (see p. 13).
7. Identify devices connected to the keypad bus (STRUCTURE HARDWARE
IDENTIFICATION LCD KEYPADS ID.).
8. Identify devices connected to the expander bus (STRUCTURE HARDWARE
IDENTIFICATION EXPANDERS ID.).
9. Exit the service mode using the END SERVICE function.
10. After a prompt appears on the keypad display whether to save the data to the FLASH
memory, press the key with the number 1. By saving a copy of the settings to the FLASH
memory, the control panel will be able to restore them from a backup copy if an error is
detected in the data stored in the RAM memory.
11. After the data are saved to the FLASH memory, the control panel will restart (the keypad
display will be blank for a moment). After the restart, the control panel should work
properly and you can proceed to programming the system.