Specifications

SATEL INTEGRA 128-WRL 17
Fig. 8. The ways to connect detectors to zones. The detector outputs are designated with
letters: A - alarm, T tamper. R=R1+R2.
5.7.1 End-of-line resistors
The value of R1 and R2 resistors is programmable within the range from 500 to 15 k (the
sum of preset values may not exceed 15 ksee PROGRAMMING manual). The factory preset
values are as follows:
R1 = 1.1 k;
R2 = 1.1 k.
If the resistor value in the keypad or expander is not programmable, in Single EOL
configuration, the 2.2 k
resistor is required, and in Double EOL (2EOL) configuration
two 1.1 k
resistors.
5.8 Connecting the sirens
If high-current output is not used, the 2.2 k
resistor should be connected between the
output and common terminals.