Specifications

SATEL INTEGRA 128-WRL 13
CKM
DTM
Distance
Number of wires
up to 100 m 1 1 1 1
100-200 m 2 2 1 1
200-300 m 4 4 2 2
Table 1.
5.5.1 Addressing devices connected to the keypad bus
Each device to be connected to the keypad bus must have its own individual address from
the 0 to 7 range. Addresses must not repeat (the control panel does not support devices
having identical addresses). It is recommended that consecutive addresses be assigned
starting from 0.
In keypads, the address is set by software means. By default, address 0 is set. When started
with factory default settings, the control panel will support all keypads connected to the bus,
irrespective of what addresses are set in them. Thus it is possible to set correct individual
addresses in the keypads and perform identification of all devices connected to the bus.
In other devices to be connected to the keypad bus, the address is to be set using the
DIP-switches or the pins.
Programming keypad address by means of the service function
1. Enter the service code (by default 12345) and press the key.
2. Using the or keys, find the SERVICE MODE item in the function list and press the
or key.
3. Start the KEYPADS ADDR. function (STRUCTURE HARDWARE IDENTIFICATION
KEYPADS ADDR.).
4. The message shown in Fig. 4 will appear on display of all keypads connected to the
control panel.
Fig. 4. Programming the keypad address with the service function..
5. Enter a proper address from the 0-7 range in the selected keypad(s). The address
change will be confirmed by four short beeps followed by one long beep.
6. To terminate the address change function, press the
key. The function will be
terminated automatically after 2 minutes from being started. Termination of the
function is equivalent to restarting the keypad (return to the main service mode
menu will follow in the keypad from which the function has been started).
Programming keypad address without entering the service mode
This method of address programming is particularly useful when due to repeating
addresses the keypad support has been disabled and entering the service mode is
impossible.
1. Disconnect the keypad power supply (KPD) and the CKM and DTM signal wires.
2. Short-circuit the keypad CKM and DTM terminals.
3. Switch on keypad power supply.
n=0...7, currently set keypad
address