Specifications

28 GSM LT-1 SATEL
Server from SMS – if this option is enabled, the address of server, to which the module is to
connect, and the port number can be entered in the content of SMS message initiating the
connection. If the address is not entered, the module will connect to the server whose
address has been programmed in the module.
Check for updates
after every reboot – if this option is enabled, the module will connect to the firmware update
server after each restart to check whether a new firmware is available.
every… days – if the module is to periodically check for updates, you must indicate every
how many days it is to take place. You can program up to 31 days. The value 0 means
that that module will not periodically connect to the firmware update server.
SMS messages
Update successful – the SMS message which will be sent after successful update of
module firmware.
No newer firmware – the SMS message which will be sent after the module has checked
that there is no newer firmware for the module.
Update failed – the SMS message which will be sent after a failed attempt of module
firmware update.
The SMS messages that informs about the update result may contain up to 32
characters.
5.2.10 "Events buffer" tab
Fig. 16. "Events buffer" tab.
The module with built-in u-blox LEON-G100 GSM telephone has a non-volatile memory
recording up to 255 events. The events are saved to memory and the "Events buffer" tab is
available, if the events buffering option is enabled (see: "Events buffering" p. 23).