Specifications
26 GSM LT-1 SATEL
5.2.8 "TCP/IP downloading" tab
Fig. 14. "TCP/IP downloading" tab.
Most of the parameters required for correct communication between the module and
the D
LOAD
10, D
LOAD
X and G
UARD
X programs using the GPRS technology can only be
programmed by means of the D
LOAD
10
program.
Communication over TCP/IP
Server address – address of the computer from which the module can be remotely
programmed. It can be entered as an IP address or as a name.
Server from SMS – if this option is enabled, the address of server, to which the module is to
connect, and the port number can be entered in the content of SMS message initiating the
connection. If the address is not entered, the module will connect to the server whose
address has been programmed in the module.
Port – the number of port on which the communication between computer and module will
take place.
Initiating SMS [119] – the control command that must be included in the SMS message sent
to the telephone number of GSM module, so that the module can start the procedure of
establishing communication with the D
LOAD
10
program (communication using the GPRS
technology).
Dload10 key – the string of 12 alphanumeric characters (digits, letters and special
characters) defining the key with which the data sent to the
D
LOAD
10 program will be
encrypted. The module will only establish connection to the program using the correct key.
Communication Integra-DloadX
Server address – the address of computer with the D
LOAD
X program, with which the module
(connected to the INTEGRA control panel through RS-232 port) is to communicate using
the GPRS technology. It can be entered as an IP address or as a name.
Server from SMS – if this option is enabled, the address of server, to which the module is to
connect, and the port number can be entered in the content of SMS message initiating the
connection. If the address is not entered, the module will connect to the computer whose
address has been programmed in the module.
Port – the number of port on which the communication with the D
LOAD
X program will take
place.
Initiating SMS [120] – the control command that must be included in the SMS message sent
to the telephone number of GSM module connected to the control panel, so that the
module can establish communication with the D
LOAD
X program using the GPRS
technology.