22 GSM LT-1 SATEL
Autorestart every [113] – you can program the time period after which the module, if not
used, will restart the telephone. From 1 to 25 hours can be entered. The "use" of the
module shall be understood as:
receiving the module outgoing call,
occurrence of the incoming call signal,
receiving acknowledgement of an SMS message sent by the module,
receiving an SMS message,
sending data by the module working as an external modem.
The first telephone restart will take place after the programmed time elapsed from saving
the settings to module.
USSD codes forwarding message [117] – the control command which must precede the
USSD code in the SMS message sent to the module. The USSD codes enable you e.g. to
check the account status of SIM card installed in the module. The SMS message sent to
the module must have the following form: "xxxxxx=yyyy." or "xxxxxx=yyyy=", where
"xxxxxx" is the control command and "yyyy" is the USSD code supported by the operator
of GSM network in which the telephone operates (it depends on the SIM card installed in
the module). Having received such an SMS message, the module will execute the USSD
code contained in it. The answer obtained from the operator is forwarded in the form of
SMS message to the telephone number from which the control command was sent.
It is not advisable to use the advanced functions available due to the USSD service if
menu is presented in response to the entered code.
Transfer unknown SMS [116] – the module can forward the received unknown SMS
messages (e.g. information received from the GSM provider) to:
phone numbers to which test transmissions are sent (see: p. 21),
phone number to which an SMS message is sent to confirm the change in module
settings received in SMS message (see: "Send SMS on change to" p. 20).
The message content is preceded by the telephone number from which it was sent. For
the modules with built-in GSM u-blox LEON-G100 telephone, the message content will be
sent in the form of 2 messages, if it contains more than 160 characters, including the
message number. For the modules with built-in other telephone model, up to 64 first
characters of the received message can be sent.
5.2.7 "Reporting" tab
Most of the parameters necessary to execute the reporting function can only be
programmed using the D
LOAD
10
program.
For further reporting related information, please refer to section "Starting the reporting"
p. 29.
Configuring the reporting
Reporting [97] – if this option is enabled, the module can report to monitoring station.
For the modules with built-in industrial-type GSM telephone other than the u-blox
LEON-G100 telephone, enabling the reporting feature will disable the feature of
PAGER message conversion into SMS messages.
INTEGRA presence supervision [98] – if this option is enabled, the status of connection
with INTEGRA control panel through RS-232 port is monitored. If loss of connection is
found, the module can report it to the monitoring station.
The connection will be monitored for the INTEGRA control panel version 1.06 or later.