Specifications
SATEL GSM LT-1 19
DNS server – IP address of DNS server to be used by the module. It is necessary for GPRS
communication, when the address of device to which the control panel is to connect
(monitoring station, computer with D
LOAD
10 program) has been entered in the form of a
name. If all addresses are entered in the form of an IP address (4 decimal numbers,
separated by dots), the DNS server address need not be programmed.
User – user name for Internet GPRS connection.
Password – password for Internet GPRS connection.
The GPRS parameters can only be programmed using the D
LOAD
10 program.
APN, user name and password have to be programmed, if the data transfer using
GPRS technology technologii (event codes, programming) is to be available.
GSM band [111] – the frequency bands which are to be supported by the GSM phone (the
parameter applies to modules with GSM u-blox LEON-G100 telephone). There are the
following bands to choose from:
850 MHz,
900 MHz,
1800 MHz,
1900 MHz.
You can select any number of bands. If all or none of them are selected, the module will
recognize that all frequencies are available and will choose the most suitable one(s).
SMS control – the module can be remotely controlled by means of SMS messages
containing the suitable control command. You can program the control commands after
receiving of which the module will:
change modem format [03];
initiate modem communication between INTEGRA / CA-64 control panel and D
LOAD
X /
D
LOAD
64 program [04];
initiate modem communication between INTEGRA / CA-64 control panel and G
UARD
X
/ G
UARD
64 program [05];
be restarted [112];
program the test transmission period [27];
program the phone numbers for test transmissions [28]…[31].
The control command may have any content, but it must consist of six alphanumeric
characters.
The control commands may not contain any diacritical marks.
You can use a space character in the control command content, but at least one of the
characters must be different from the space character.
Set modem format [03]
The SMS message sent to the module to set the modem format must have the following
form: xxxxxx=yy, where "xxxxxx" is the control command and "yy" is the modem format
code (see Table 1 p. 18). Having received such an SMS message, the module will
change the modem format
Call to service [04]
The control command can start the remote modem communication between the
INTEGRA control panel and the D
LOAD
X program, or between the CA-64 control panel