Specifications

SATEL GSM LT-1 11
[41
**
] – a sequence of up to 4 digits which will replace the "+" character in the phone number
from which the CLIP connection is established to the module.
[97
**
] – parameter defining whether the module is to execute the reporting function:
0 – no,
1 – yes.
[98
**
] – parameter defining whether the module is to monitor the status of connection with
INTEGRA control panel through the RS-232 port:
0 – no,
1 – yes.
The connection will be monitored for the INTEGRA control panel version 1.06 or later.
[99
**
] – parameter defining whether the module is to answer to CLIP (see: "CLIP answering"
p. 21):
0 – no,
1 – yes.
[99
**
] – enter the digits 7890 and confirm with the [#] key to start the module test mode. It
allows you to check the LEDs on the module electronics board for proper functioning. After
the test mode is started, the LEDs will go off. Then, each of them (in order: STAT, SIG,
TX, RX) will light up for about 1 second and the FLT output will activate. When the LED
testing procedure is finished, the module will return to the state from before starting the
test mode.
[105
**
] – parameter defining the number of unsuccessful attempts to send the event through
the given reporting channel, after which the module will attempt to send the event through
the next channel. You can program values from 2 to 255 (default: 3).
[111
**
] – a sequence of 4 characters defining which GSM frequencies are to be used by the
GSM phone installed in the module (the parameter refers to the modules with u-blox
LEON-G100 GSM phone):
1. character – 850 MHz (0 – no; 1 – yes);
2. character – 900 MHz (0 – no; 1 – yes);
3. character – 1800 MHz (0 – no; 1 – yes);
4. character – 1900 MHz (0 – no; 1 – yes).
You can select any band combination. If you select all four or none, the module will
interpret it as all frequencies being available and will select the most suitable one(s).
[112
**
] – 6 digits representing the SMS control command to be sent to module to restart it.
[113
**
] – parameter defining the time after which the module, if not used, will restart the
phone (see: "Autorestart every" p. 22). You can enter from 1 to 25 hours.
[114
**
] – a sequence of up to 8 characters (digits: 0-9 and characters: #,
*
, +) defining the
country code, which should be programmed, if the PAGER type cellular phone numbers to
be notified in the control panel are not preceded by it.
[115
**
] – parameter defining whether the SMS and DTMF control can be executed:
0 – from any phone number,
1 – from authorized phone numbers only (see: "SMS control only from list of messaging
tel. numbers" p. 20).
[116
**
] – a sequence of 5 characters defining the phone numbers to which the module is to
send the received SMS messages:
1. character – 1. phone number for test transmission (0 – no; 1 – yes);
2. character – 2. phone number for test transmission (0 – no; 1 – yes);