CD-2 Curtain detector EN Firmware version 1.00 cd-2_en 10/21 SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND tel. +48 58 320 94 00 www.satel.
IMPORTANT The device should be installed by qualified personnel. Prior to installation, please read carefully this manual. Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty. The rating plate of the device is located on the enclosure base. SATEL aims to continually improve the quality of its products, which may result in changes in their technical specifications and software.
CONTENTS 1 2 3 4 5 6 7 Features ........................................................................................................................... 2 Specifications ................................................................................................................... 2 Description ........................................................................................................................ 2 Supervision features ...............................................................
2 CD-2 SATEL The CD-2 detector detects motion in the protected area. Its coverage area is shaped like a curtain which makes it suitable as a component of parameter protection. This manual applies to the detector with electronics version 1.0. 1 Features Motion detection with passive infrared sensor (PIR). Adjustable detection sensitivity. Digital motion detection algorithm. Digital temperature compensation. Custom-designed lens for SATEL’s short-range curtain detectors. LED indicator.
SATEL CD-2 3 LED The red LED indicates: warm-up – flashing for about 30 seconds; alarm – ON for 2 seconds; trouble – ON for entire duration of the trouble. You can enable / disable the alarm indication by using the LED pins (Fig. 1). Put a jumper across the pins to enable the alarm indication. 4 Electronics board Do not remove the electronics board from the enclosure to avoid damage to the components on the board. terminals: +12V COM TMP NC - power input. common ground. tamper output (NC).
4 CD-2 SATEL 5 Selecting a mounting location Do not install the detector outdoors (A). Do not point the detector towards heat sources (B), air conditioners (C) or fans (D). Install the detector in a place where the expected direction of the intruder movement will be across the coverage pattern (Fig. 2). 6 Installation Disconnect power before making any electrical connections. The detector is designed for indoor installation.
SATEL CD-2 5 1. Remove the detector cover (Fig. 3). The enclosure opening tool, shown in the illustration, is included in the detector delivery set. 2. Make a screw hole in the enclosure base. 3. Pass the cable through the prepared hole (Fig. 4). 4. Use wall plugs (anchors) and screws to mount the enclosure base to the surface (Fig. 4). The wall plugs delivered with the device are intended for concrete, brick, etc.
6 CD-2 SATEL