WARNING In order to avoid any operational problems with the control panel, it is recommended that you become familiar with this manual before you start using the equipment. Making any construction changes or unauthorized repairs is prohibited. This applies, in particular, to modification of assemblies and components. Maintenance or repair operations should be performed by authorized personnel (i.e. the installer or factory service). Telephone terminals of the panel should be connected to PSTN lines only.
CONTENTS Technical Reliability of the Alarm System........................................................................2 Alarm System Operating Costs .......................................................................................2 CA-10 Control Panel........................................................................................................2 Armed Modes ..................................................................................................................3 Full armed mode..
Technical Reliability of the Alarm System ar m .co m .m y The alarm system is built of the devices whose reliability is vital in effectiveness of offered protection. The elements of the alarm system are subject to various outside influences, for example weather conditions (outside signaling devices), lightning (overhead telephone lines, power lines, outside signaling devices), mechanical damage (keypads, detectors).
CA-10 3 SATEL ea l Armed Modes ar m .co m .m y answering phone calls and informing the user of the system status (whether there was an alarm condition since last arming), MONITORING - communication with telephone monitoring stations (real-time transmission of detailed information about selected events in the protected facility), printing current information about all the system events on an external printer.
4 USER MANUAL CA-10 Operating Instructions ht tp :// ww w. ea l ar m .co m .m y Operating of the alarm system consists basically in arming and disarming the system and responding appropriately to the information the control panel may signal on the keypad. The LED keypad conveys information on the status of the alarm system by means of several LEDs and audible signals.
CA-10 5 SATEL LED Functions (red color) – blinking LED indicates alarm in partition. The LED goes out after alarm reset (when none of LEDs is blinking, the alarm cause will be shown by the function "Viewing alarm log". The alarm may have been caused by a zone not displayed in the partition, or the zone belonged also to another partition, where alarm was cleared). ALARM (yellow color) – blinking LED indicates there is a failure in the alarm system.
6 USER MANUAL CA-10 States of control panel armed zones in LCD keypad The LCD keypad can indicate in the bottom line of its display, either periodically or permanently, the state of control panel armed zones. Given below are symbols which may be displayed at the successive items (1–16) and their meaning.
CA-10 7 SATEL In some keypads, the numeric keys are provided with letters. They may help the user memorize a code by associating it with a particular word (e.g. the „[5][6][2][7][2]” code corresponds to the word „KOBRA”). When creating a new user access code, the master user assigns a so-called authority level to it , i.e. determines which of the panel functions are available to the particular user, and which are not.
8 USER MANUAL CA-10 arming is not affected by any detectors being violated at the time. The installer can also install a special key for quick arming of the system. Disarming and clearing alarm [CODE][#] ea l ar m .co m .m y When the control panel is armed ( [ARMED] LED is on or blinking) or signals an alarm ( [ALARM] LED is blinking), it can accept only one command: disarming the system or clearing the alarm.
CA-10 9 SATEL tone followed by a 4-second pause - this signal corresponds to the telephone ringing tone) hang up and call again (within 5 minutes) - the panel will answer the second call immediately. The installer decides if the function is to be activated and how the control panel will answer the phone calls (number of rings, double calling, etc.) Control panel interfacing with DTMF (MST-1) control module ar m .co m .
10 USER MANUAL CA-10 Changing display mode of system state key Pressing and holding down the key for about 3 seconds will temporarily change the operating mode of LCD keypad: instead of displaying text messages on the system status it will display the state of armed zones in LCD standard (and vice versa). The keypad will automatically return to the operating mode specified by the installer after 40 or 140 seconds since the last key was pressed (depending on how the „long backlight” option is set).
CA-10 11 SATEL :// ww w. ea l ar m .co m .m y In the LED keypad, the [TROUBLE] and [ARMED] will go on, the [ALARM] LED will start blinking, while information on the last alarm will be shown on the LEDs 1-12. Pressing any key (except for the [*] key, which stops viewing the alarms log immediately), you can reach information on the previous alarms, until the end of the events log.
12 USER MANUAL CA-10 10 - problem with transmission to monitoring station 11 - not used 12 - output 4 trouble The previously detected troubles are displayed on repeatedly pressing any key. The [*] key cancels the troubles log viewing function. Current trouble check-out [7] y When the control panel signals a trouble detection (the [TROUBLE] LED is blinking), you can activate the current trouble check-out function by holding down the key [7].
CA-10 13 SATEL .co m .m y 9 - telephone line loss - the message indicates that the telephone line is cut off. It may also indicate lifting the receiver of a telephone connected to the same line for longer than the time specified by the installer.
14 USER MANUAL CA-10 Panic alarm [#] This function activates the panic alarm from the keypad. The functions of keypad alarms may be disabled by the installer. User functions w. ea l ar m .co m .m y If the control panel is disarmed and is signaling no alarm, there are some functions, useful in everyday operation of the alarm system, available to the users. The access to specific functions depends on the user's authority level.
CA-10 15 SATEL User access code change [CODE][*][1] This function enables changing the access code of the user by whom it was activated. Having called the function, enter a new code and confirm it by pressing the [#] key. The keypad will confirm the code change by a sequence of beeps (the LCD keypad will display the name of the user, whose code has been changed). The function is available to the master user and users with authority level 1, 2 or 7.
16 USER MANUAL CA-10 ea l ar m .co m .m y The text mode is signaled by * in the upper right corner of the display. Numeric keys in text mode insert letters at the cursor position according to the preceding table. Lowercase characters are entered by pressing a numeric key twice. keys enable the previous/next character selection. In numeric mode key deletes the character before the cursor, and key switches between insert/typeover modes.
CA-10 17 SATEL confirmation, if the selected user is to be deleted. If not, press the [*] key, if yes, press the [#] key. The numbers of users from 10 to 12 can be entered by pressing two keys, first the key of tens [*], then the key of units (from 0 to 2). In the LCD keypad, the user indicated by the cursor (flashing field) will be deleted. On pressing and holding down the or key the name of the user indicated with the cursor appears. The cursor can be positioned with .
18 USER MANUAL CA-10 Silent arming [CODE][*][5] In the silent armed mode the alarms are only signaled in keypads and reported to the monitoring station. The installer decides if the silent armed mode is to be active in the entire protected facility or if a selected area will remain disarmed. The function is not available to the users with authority levels 5, 6, 0. Time setting [CODE][*][6] .co m .m y The function enables setting the panel’s clock.
CA-10 19 SATEL After calling the function, the control panel generates two short beeps and waits for the output number key (1-6) to be pressed. The control consists in changing over the status of the given output to its opposite, i.e. the inactive output gets activated and vice versa. Provision is made for multiple control of the same output or control of different outputs of the SWITCH BI type after single calling of the function.
ea la rm .co m .m y - hold down for 3 sec. to display current trouble condition TROUBLE DISPLAY: 1,2,3 - Output 1,2,3 trouble 4 - 230V AC loss 5 - Low battery 6 - Keypad supply fail 7 - Time not set 8 - Printer trouble 9 - Telephone line loss 10 - Problem with transmission to station 11 - Telephone line trouble 12 - Output 4 trouble all off - System memory fault // tp : - hold down for 3 sec. to activate AUXILIARY ALARM ht [*] - hold down for 3 sec.
LCD DISPLAY: time and date or partition name and system status message ALARM - alarm in the partition .co m .m y - hold down for 3 sec. to GO TO selected partition ea la rm - hold down for 3 sec. to activate alarm log viewing ht tp : // ww w. pressing the key for 3 seconds activates Trouble Log Review - hold down for 3 sec. to activate current trouble condition display - hold down for 3 sec.