Instruction Manual

Chapter 5 Configuring the EM720
General Meter Setup
EM720 Power Quality and Revenue Meter 81
Display
Label
Parameter Options Default Description
Auto-Scroll Auto-Scroll
Interval
Disabled,
2-10, 15, 20, 25, 30
seconds
5 Defines the display scroll
interval or disables auto-
scroll
Scroll Seq. Auto-Scroll
Sequence
1-2, 1-3, 1-4,
1-5, 1-6, 1-7, 1-8, 1-9
1, 5-9
1-2, 5-9
1-3, 5-9
1, 6-9
1-2, 6-9
1-3, 6-9
1-4, 6-9
1, 7-9
1-2, 7-9
1-3, 7-9
1-4, 7-9
1, 8-9
1-2,8-9
1-3,8-9
1-4,8-9
1, 9
1-2, 9
1-3, 9
1-4, 9
1, 9 Selects the display
sequence for auto-scrolling
from 9 data displays (see
Data Displays
for display
enumeration)
Auto-Return Auto-Return Disabled,
1-5, 10, 15, 20, 25, 30
min
5 Defines the time delay
before returning to the
default page
Def. Page Default Page 1/2 – 1/10
2/1 – 2/10 …
9/1-9/10
1/2 Specifies the default
display/page. If a page is
not available in present
mode, the following
available page will be
displayed.
Backlight Backlight Time Continuous,
1-10 min
1 Defines the time while the
backlight is ON
Diag. Icon Diagnostic
Message Icon
Disabled
Enabled
Enabled Disables/Enables the
blinking diagnostic icon in