Owner's manual
Appendix: Technical Specifications 53
Accuracy, % Range Display resolution (%Rdg)
Parameter Full scale Rdg FS Conditions @
range
Apparent energy according to power accuracy 0 to 99,999
MVAh
1 kVAh
@
1 to 99,999 kVAh
10 kVAh
@
100 to 999.99 MVAh
100 kVAh
@
1,000 to 9,999.9 MVAh
1MVAh
@
10,000 to 99,999 MVAh
PT = external potential transformer ratio CT, CT Primary Current = primary current rating of external current transformer
FSU = voltage full scale FSI = current full scale U
1
= voltage fundamental I
1
= current fundamental
@ 10% to 120% of voltage FS and 2% to 120% of current FS
Higher resolution is achievable via communications
Where the current is > 10% FS, the energy accuracy is better than 1.5% Rdg.
80% to 120% of voltage FS and 10% to 100% of current FS
Additional Notes
1. Accuracy is expressed as ± (percentage of reading + percentage of full scale) ± 1 digit. This does not include inaccuracies introduced by the
user's potential and current transformers.
2. Specifications assume: voltage and current wave forms with THD ≤ 5% for kvar, kVA and PF; reference operating temperature: 20 - 26°C.
3. Ordinary measurement error is considerably less than the specified accuracy which indicates maximum error.