3-WAY WIRING
Note: A single pole or
3-way switch can be
used alongside the
smart dimmer.
IMPORTANT: The
switch must be
installed in the “LINE”
wall box and the
smart dimmer must
be installed in the
“LOAD” wall box.
Ensure that the following
connections are made
at the dimmer:
“LINE” wire
to the AC-L terminal
“LOAD” wire
to the LOAD terminal
Traveler wire
to the YL/RD terminal
Neutral wire
to the AC-N terminal
Ground wire
to the GND terminal
Ensure that the following
connections are made
at the switch:
“LINE” wire
to one terminal
Traveler wire
to the other terminal
Ground wire
to the GND terminal