Time-Controlled Functions K
Purpose
With this application program, you
can configure the scale to perform
certain functions (such as automatic
printout of values, store value in
totalization memory) at a given time
or after a set interval.
You can use this application in
combination with any program
chosen from Application 1 (such as
counting, weighing in percent)
and one from Application 3 (such as
totalizing, formulation).
Features
Time-controlled activation of scale
functions:
one time only, at a given time
(
Setting= is displayed in
the text line)
repeatedly, at given intervals
(Interval= is displayed in
the text line before the function is
started, and
Repeat = is displayed after
the function has been started)
Functions that can be time-
controlled include:
Acoustic signal (beep)
Lock in readout
Automatic printout of values
Store values for totalizing,
formulation or statistics
Print time in addition to
weight value
Store value depending on
the stability parameter
Tare the scale after printout
of weight values
Press the corresponding soft key to
cancel time-controlled functions
Factory Settings
Function after time interval:
Automatic printout
of values
Automatic function restart: On
Storage mode:
Without stability
Print then tare: On
Soft Key Functions
Stop Stop the application
Quit Confirm performed
function (e.g., »Lock in
readout« or »Beep«)
Interv Store input interval for
time-controlled functions
Set. Store input time for
one-time performance
of function
Start Start timer function
Printout for Time-Controlled
Functions
If the »Automatic printout of values«
parameter is set, the time and weight
(or other value) are printed out.
Time: 10:15:00
N + 150.00 g
Time: Time that the values were stored
N: Net weight