Operating instructions
133
Operating the Scale
Verification of Intrinsic Safety
1
Blatt
Page
8
von
of
Maßstab /
Scale
---
FCT01-X.. /
Ausgabe / Revision
01
Freigabe
Released by
Geprüft
Reviewed by
Erstellt
Written by
25.08.05
25.08.05
25.08.05
Datum
Date
Klausgrete
Klausgrete
Klausgrete
Name
Material
65638-099-60-A4
Benennung / Title
Änderung / Alteration
---
Zeichnungs-Nr. / Drawing number
Sartorius cable; attached
to power supply / Ex
rechargeable battery pack,
adjustable; max. length:
50m
Hazardous area
Zones: 1, 2
Gas: IIC T4
FCT01-X..
II 2 G EEx ib IIC T4
Circuit Vi Ii Pi Ci Li
V_1 12.6 V 133 mA 1.46 W 0 nF 0
V_2 12.6 V 133 mA 1.46 W 0 nF 0
V_3 8.6 V 187 mA 1.61 W 300 nF 0
V_4 12.6 V 150 mA 1.89 W 100 nF 0
Alternative
connections
YPS02-X.. /YPS02-Z..:
Circuit Uo Io Po Co Lo
V_1 12.6 V 133 mA 1.46 W 1 µF 300 µH
V_2 12.6 V 133 mA 1.46 W 1 µF 300 µH
V_3 8.6 V 187 mA 1.51 W 4 µF 300 µH
V_4 12.6 V 150 mA 1.68 W 1 µF 300 µH
YPS02-XV24 / YRB02-X:
Circuit Uo Io Po Co Lo
V_1 12.6 V 133 mA 1.43 W 0.5 µF 300 µH
V_2 12.6 V 133 mA 1.43 W 0.5 µF 300 µH
V_3 8.6 V 186 mA 1.49 W 0.8 µF 200 µH
V_4 12.6 V 150 mA 1.65 W 0.5 µF 300 µH
Power supply
(100-240 Vac)
YPS02-Z.R
II (2)G [EEx ib] IIC
II (1) D
Power supply
(100-240 Vac)
YPS02-X.R
II 2 G EEx d [ib] IIC T4
II 1 D T135°C IP65
Power supply
(22-28 Vdc)
YPS02-XV24
II 2 G EEx e m [ib]IIC T4
II 1 D IP6X T80°C
Ex rechargeable battery
pack
YRB02-X
II 2 G EEx e m [ib]IIC T4
II 1 D IP6X T80°C
Non-hazardous area
Power Supply