Menu item 11-4-1 is displayed.
If the “Trade” configuration is active (class l), menu item 11-4-2 is shown
(see the last paragraph on this page).
) Activate the menu item.
The configuration for the scale interval d is displayed.
The flashing number marks the current cursor position. This marked number can be changed.
The number in the entry field can be changed to the desired value by repeatedly moving the
cursor and changing the respective number.
Navigation for Input
(For more details: see the chapter entitled “Operating Design"):
Exit an activated menu item without storing entry (For example in the case of an inadvertent
selection): Press the ( key.
Store displayed contents (in the present example d = 0.01 lb):
Press the ) key for a long time (> 2 sec. ).
Move the cursor 1 position to the right (in the present example from the 1st zero to the
decimal point): Press the ) key. This confirms the character (number, minus sign or
decimal point) at the previous cursor position. If the cursor is at the far right, pressing )
confirms the input.
Move the cursor 1 position to the left: Press the ( key. If the cursor is in the 1st position
(all the way to the left), then you exit the menu item.
Delete the displayed contents and overwrite with your own input: press the k key.
A zero is written in the first position.
Every time the k key is pressed, you scroll one page forward (1, 2 ... 9).
In the 1st position (all the way to the left), there is a minus sign “-" after the number “9"
if you want to enter a negative number (... 8, 9, -, 1, 2 ...). In all other cursor positions,
there is a decimal point “." after the number “9" which can be selected (... 8, 9, ., 1, 2 ...).
Press the p key: Scroll backwards.
The same characters are available for selection as with the k key:
1st position: ... 1, 0, -, 9, 8, ..., all other positions: ... 1, 0, ., 9, 8, ....
Define the scale interval d for the weighing instrument:
If the default value displayed (here: “0.001 kg") corresponds with the desired scale interval,
then store the value by pressing the ) key (for longer than 2 sec.)
Otherwise use the k and ) keys (if necessary, also the ( and p) keys) to overwrite
the default value and confirm by pressing the ) key.
In the present example, the scale interval d is set to 0.1 lb.
) Confirm new setting.
If the “Trade configuration” is active (class l), this menu item is opened automatically
(if “Multiple-range scale” is set: 11-5-2; with “Multi-interval scale”: 11-6-2). If the
“Standard configuration” is active, this item is not shown. See also the remarks on the
previous page.