User Manual

Joule 2.0 User Guide page 46
Joule 2.0 User Guide page 47
1. Press and release the [MODE] button until Menu mode is displayed.
2. Press [JOYSTICK] in and release to select Sensors.
3. Press [JOYSTICK] in and release to select Power Sensor.
4. Press [JOYSTICK] up/down to highlight the desired Sensor Type. For CycleOps PowerTap Plus series hubs
press [JOYSTICK] in and release to select Add PowerTap. For CycleOps Pro Series indoor cycles select Add IC
Power. For any ANT+ compatible power sensor select Add ANT+.
5. Make sure the power sensor is awake and isolated from other active sensors by 65 feet/20 meters. For Power-
Tap and IC Power sensors rotate the hub/wheel at least one revolution. For ANT+ sensors see that sensors user
guide for information on waking up the sensor.
6. Press the [JOYSTICK] in and release to Start Pairing. Pairing may take up to 60 seconds. Once pairing is suc-
cessful, the sensor ID will be displayed.
7. Press [JOYSTICK] up/down to highlight Name. Press [JOYSTICK] in and release to select name and change the
name of the paired power sensor.
8. For PowerTap sensors only, press [JOYSTICK] up/down to highlight the wheel circumference and press [JOY-
STICK] in and release to select wheel circumference. Press [JOYSTICK] up/down to change wheel circumference.
Press JOYSTICK in and release to save changes. For a list of common wheel circumferences see FAQ section.
Chapter 6: Sensors
Setting Up Power Sensors
Joule 2.0 is compatible with many ANT+ sensors, each having a unique code. A sensor is dened
as any ANT + compatible power meter, cadence sensor, speed sensor, heart rate strap and
CycleOps resistance unit. Joule 2.0 needs to be paired to each sensor to ensure proper function-
ality. Common CycleOps power sensors include the PowerTap hub, 300 Pro and 400 Pro indoor
cycles. Once set up, sensors can be managed using PowerAgent software. Note: if you purchased
a CycleOps 200 Pro, 300 Pro, 400 Pro indoor cycle or PowerBeam trainer all available sensors have
been paired at the factory.
Setting Up Power Sensors...continued.
9. Press [JOYSTICK] up/down to highlight Auto Zero Yes or No. Press [JOYSTICK] in and release to select Auto
Zero Yes or No. Press [JOYSTICK] up/down to change Auto Zero Yes or No. Note: Auto Zero setting should
remain set to Yes in all cases except when using a Track PowerTap.
10. Press [JOYSTICK] up/down to highlight Activate Sensor.
11. Press [JOYSTICK] in and release to Activate Sensor. Note: active sensor is designated by a hash mark next to
the sensor name in the sensor list. When switching speed sensors, be sure to activate the appropriate sensor.
12. Once a sensor has been paired and activated Joule 2.0 will automatically nd the active sensor whenever it
is turned on.
Note: multiple sensors can be stored by Joule 2.0 but only one can be active per sensor category at a given time.
Chapter 6: Sensors