Manual

4
800-810-WIRE (9473) • www.sargentlock.com A7455B
Profile Series Exit Device
Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Rim Installation Instructions for Rim Type
Exit Device 8877/8878
3
NOTE: BEFORE STARTING
• This device is non handed
• Door should be fitted and hung
• Verify box label for size of exit device,
function and hand
• Install mullion in frame, if used
Step #1 – Exit Hardware & Door Prep
Prep Door according to Exit installation instructions A6770
Step #2 – Installation of Outside and Inside Trim
2. Inside Trim
• Route “ET” harness along track cutout for wood doors and
access hole for metal doors
• Mount exit chassis carefully. DO NOT PINCH HARNESS WIRES
• “ET” spindle will engage into the hub of exit device chassis
• Secure chassis with (2) 1/4-20 x 2 3/8" flat head
machine screws
1. Outside Trim
• Route harness through under cut of cylinder hole
and out to other side of door
• Mount “ET” control onto door
4. Securing Cylinder
• Secure cylinder to exit chassis using
(2) #12-24 x 1 7/8" connecting screws
• Fasten exit chassis to door using (4) #10 wood
screws or #10-24 machine screws
3. Cylinder Installation
• Insert cylinder into “ET” control
• Mate cylinder tailpiece into hub of exit device
chassis
• Make sure “ET” harness is clear of cylinder and
cylinder tailpiece
(#34)
Cylinder
ET Control
Wire
harness
Center line for
(2) 1/4 - 20 x 2 3/8’’
flat head
machine screws
Wire harness
(2) 1/4-20 x 2-3/8’’
Flat head
machine screws
secures ET
Exit Chassis
(2) #12-24 x 1-7/8’’
Flat head
connecting
screws for
cylinders
(4) #10 Wood
screws or #10-24
machine screws
Outside
of door
Inside
of door
Outside
of door
Inside
of door