Installation Instructions For Profile Series Exit Device A7455B Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. FOR ASSISTANCE, CONTACT SARGENT AT 800-727-5477 or www.sargentlock.
Profile Series Exit Device Table of Contents Page 1 Warning and Items Supplied . . . . . . . . . . . . . . . . . . . 1 2 Parts Breakdown . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 3 Rim Installation Instructions . . . . . . . . . . . . . . . . . 4-7 4 Mortise Installation Instructions . . . . . . . . . . . . . 8-11 5 Operational Check . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Profile Series Exit Device 1 Warning Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Profile Series Exit Device 2 Parts Breakdown 8977/8978 x ET x Lever Design Profile Series Mortise Exit Device ITEM 1 1 2 2 2 Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Profile Series Exit Device 2 Parts Breakdown (Continued) 8877/8878 x ET x Lever Design Profile Series Rim Exit Device 2 2 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 PART NUMBER 52-2475 52-2474 52-2432 52-2431 68-1397 52-0176 52-2460 52-2461 52-2462 68-1396 52-0175 52-2441 52-2448 52-2455 52-0170 01-1212 01-0297 52-0033 01-1500 01-0803 52-0253 52-2425 Consult Factory 52-2556 01-4451 13-0074 77-0685 68-4261 68-4263 68-0406 97-0052 DESCRIPTION Outside Escutcheon Assembly (PA) Outside Escutcheon Assembly (LK
Profile Series Exit Device 3 Rim Installation Instructions for Rim Type Exit Device 8877/8878 Inside NOTE: BEFORE STARTING • This device is non handed • Door should be fitted and hung • Verify box label for size of exit device, function and hand • Install mullion in frame, if used Left Hand Reverse Bevel "LHRB" Outside Right Hand Reverse Bevel "RHRB" Step #1 – Exit Hardware & Door Prep Prep Door according to Exit installation instructions A6770 Step #2 – Installation of Outside and Inside Trim 1.
Profile Series Exit Device Installation Instructions (Continued) Step #3 – Apply Fire Stop Plate (Required for 12-) 1. Fire stop plate for 12-devices • Fire stop plate required in all fire rated doors (12-) • Drill (2) 1/8" diameter holes if the door is not supplied with them • Secure fire stop plate to door with (2) #8 x 1/2" self tapping screws CL of 1-1/2" Dia. 1-1/2'' DIA. (2) 1/8" Dia.
Profile Series Exit Device Rim Installation Instructions (Continued) Step #4 – Installation of Outside and Inside Escutcheon 1. Insert wires and connector from the outside of the door, through the fire stop plate (if required) Wires & connector go through fire stop plate • For non-12- exit devices, feed wire harness from keypad assembly through hole in door Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Profile Series Exit Device Rim Installation Instructions (Continued) + + + - + + + - Step #6 Rail Assembly Attach rail assembly according to exit installation instructions A6770 800-810-WIRE (9473) • www.sargentlock.com • A7455B 7 Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Profile Series Exit Device 4 Installation Instructions for Mortise Type Exit Device 8977/8978 NOTE: BEFORE STARTING • Check hand of door - this device is not reversible • Door should be fitted and hung • Verify box label for size of exit device, function and hand Inside Left Hand Reverse Bevel "LHRB" Outside Step #1 - Exit Hardware & Door Prep Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Profile Series Exit Device Mortise Installation Instructions (Continued) Step #2 – Install Outside & Inside Trim 1. Exit Chassis: • Route “ET” harness along track cutout for wood doors and access hole for metal doors. • Mount exit chassis carefully. Do not pinch harness wires • Position exit chassis on door so that lever arm is under rear section of mortise lock lever. Then lift up until latchbolt is completely retracted.
Profile Series Exit Device Mortise Installation Instructions (Continued) Step #3 – Apply Fire Stop Plate (Required for 12-) 1. Fire stop plate for 12-devices • Fire stop plate required in all fire rated doors (12-) • Drill (2) 1/8" diameter holes if the door is not supplied with them • Secure fire stop plate to door with (2) #8 x 1/2" self tapping screws CL OF 1-1/2" Dia. 1-1/2'' Dia. (2) 1/8" Dia.
Profile Series Exit Device Mortise Installation Instructions (Continued) Step #4 – Outside Keypad Escutcheon 1. Insert Wires and Connector • From the outside of the door through the Fire Stop Plate (if required) Wires & Connector go through fire stop plate • For non 12- exit devices feed wire harness from keypad assembly through hole in door Inside of door Outside of door Step #5 – Rail Assembly Attach rail assembly according to Exit installation instructions A6705 800-810-WIRE (9473) • www.
Profile Series Exit Device 5 Operational Check • Place key into cylinder and rotate key • The key will retract the latchbolt, the key should rotate freely • Inside rail retracts latchbolt • Enter 1234* to unlock outside lever handle and retract latchbolt • If a card or prox is used, present them as shown below. Microprox Tags are presented like cards. Insert into dish Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Profile Series Exit Device 6 Programming Instructions for Keypad Operations Only • Soflink™ Plus must be used with (PA) controller for programming • The Master Code is always User “01”. The Master Code assigns the Emergency and Supervisory Codes. It is also used for programming. Users are deleted through the Master Programming Code only • The Emergency Code is always User “02”.
Profile Series Exit Device Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Profile Series Exit Device Yellow Yellow Yellow Yellow Yellow LED LED LED LED LED blinks blinks blinks quickly blinks slowly (If solid, see note) goes out Yellow Yellow Yellow Yellow LED LED LED LED blinks blinks blinks quickly goes out (If solid, see note) For additional information, see “Transaction Log”. Note: Seq. # 0 is the programming request to output the entries. Sequence numbers 1-9 are the actual entries.
Profile Series Exit Device To Enable/Disable A User 99# Master Code* Yellow LED blinks 56# 0# (Enable) or 1# (Disable) (User No. 04-100)# Yellow LED blinks * Yellow LED blinks quickly * Yellow LED blinks slowly (If solid, see note) * Yellow LED goes out To Set Unlock Time 99# Master Code* Yellow LED blinks 11# (1-99 sec)# 0# Yellow LED blinks * Yellow LED blinks quickly * Yellow LED blinks slowly (If solid, see note) * Yellow LED goes out The Unlock Time is adjustable for Momentary Operation.
To Change the Supervisor Code 99# Master Code* 50# 1# 3# Supervisory (1-6 digits)* Supervisory (1-6 digits)* * Yellow Yellow Yellow Yellow Yellow LED LED LED LED LED blinks blinks blinks quickly blinks slowly (If solid, see note) goes out Enter A User Code 99# Master Code* 50# 1# (User Number 04-500)# User Code (1-6 digits)* User Code (1-6 digits)* * Yellow Yellow Yellow Yellow Yellow LED LED LED LED LED blinks blinks blinks quickly blinks slowly (If solid, see note) goes out Enter A Passage (Mainta
Profile Series Exit Device To Clear the Entire Memory 99# Master Code* 46# 00000# 00000# * * * Yellow LED blinks Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks very fast for 10 sec.
Profile Series Exit Device Set Unlock Time 99# Master Code* Yellow LED blinks 11# (1-99 sec.)# 0# Yellow LED blinks * Yellow LED blinks quickly * Yellow LED blinks slowly (If solid, see note) * Yellow LED goes out The Unlock Time is adjustable for momentary operation. A 5 second unlock time is recommended to extend battery life. Once the unlock time is entered, it is the same for ALL users except 02. To Enable/Disable A User 99# Master Code* 56# 0# (Enable) or 1# (Disable) (User No.
Profile Series Exit Device To Erase Transaction Log 99# Master Code* 76# 00000# 00000# * * * Yellow Yellow Yellow Yellow Yellow LED LED LED LED LED blinks blinks blinks quickly blinks slowly (If solid, see note) goes out Note: If the Yellow LED becomes solid rather than blinking, a mistake has been made. Depress the * Button until the Yellow LED goes out and start programming again.
Profile Series Exit Device First Time Programming (Using any HID Card and the PA controller Comm Enable push button) Note: Card can also be a Fob or Prox Tag 1. Create / Open Door File for PA Lock 2. Connect lock to PC (or PDP) using connectors and cable 3. On PC - Click "Send to Door" On PDP – Click "Up/Down" 4. Wake up the PA lock by presenting a HID Card at the PA prox assembly. Message appears on PC "Please enter your communication code at the controller and then click OK.
Profile Series Exit Device 7 Chain Programming When programming multiple User Numbers and Codes into the LK, LU or PK Keypad Lock, it is not necessary to leave and re-enter the programming Mode (50) for each entry. Multiple entries may be chained together and the three different types of user codes (Standard, Passage and One Time) may be mixed. The format to be used is as follows where: “T” is the Type of user code with “1” Standard, “2” Passage and “3” One Time.
Profile Series Exit Device 8 Transaction Log To output the last 15 or 1000 transactions, enter 99 # Supervisory or Master Code * 70 # 0 # 0 # **. • Examples on this page are for the 100 user, 15 transaction unit + + + - + + + - LK Note: Seq. # 0 is the programming request to output the entries. Sequence numbers 1-9 are the actual entries.
Profile Series Exit Device Supplemental – Individual “Door” Log Sheet (LK, LU, PK and PA) Lock Model: Door Name: Location: Function Master Code Emergency Code Supervisory Code Table 1: Main Codes - User Programmed “Door” Log User Number Default Code User Programmed Code 01 1234* 02 4321* 03 *Note: If entire memory is cleared, you must reprogram Emergency code. The Master code resets back to 1234*. Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
800-810-WIRE (9473) • www.sargentlock.com • A7455B 25 Copyright © 2003, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
SARGENT Manufacturing 100 Sargent Drive New Haven, CT 06511 USA 800-727-5477 • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets. Copyright © 2003, 2008 Sargent Manufacturing Company, an ASSA ABLOY Group company.