Instructions For Installation of Keypad Rim/Mortise Exit Devices KP8877 and KP8878 KP8977 and KP8978 KP8877 A7137B Copyright © 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Table of Contents 1 2 3 4 5 Copyright © 2006, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. 6 7 Page Items Supplied.....................................................................................1 Parts Breakdown..............................................................................2-3 Rim Installation Instructions for KP8800 Series.
1 Items Supplied with Exit Device Items included in your KP8877 and KP8977 Series Exit Device carton: • Outside Escutcheon with Keypad • Outside motorized Trim Assembly • Exit Device • Mortise cylinder for KP8977 • Rim cylinder for KP8877 • Inside Escutcheon with Circuit Board and Battery Pack • 4 C alkaline batteries • Screw Pack Items included in your KP8878 and KP8978 Series Exit Device Carton: • Outside Escutcheon with Keypad • Outside Motorized Trim Assembly • Exit Device • Inside Escutcheon with Circu
KP8877/KP8878 x ET x Lever Design Keypad Operated RIM Exit Device 2 Parts Breakdown ITEM # 1 1 1a 1b 1c 1d PART # 52-2340 52-0004 52-2299 52-2303 52-0033 01-1500 52-0254 2 2 2a 2b 2c 2d 2e 3 3 3a 3b 3c 52-2302 52-0087 52-2561 52-0069 01-1212 01-0297 01-1119 Consult Factory Consult Factory 52-2556 01-4451 13-0074 52-0263 4 4 4a 4b 68-4261 68-4263 68-0406 97-0052 DESCRIPTION *Outside Escutcheon Assembly (with keypad assy) *Outside Escutcheon only Keypad (with ribbon cable) less escutcheon Screw Pack (I
KP8977/KP8978 x ET x Lever Design Keypad Operated MORTISE Exit Device 2 Parts Breakdown PART # 52-2340 52-0004 52-2299 52-2303 52-0033 01-1500 52-0254 2 2 2a 2b 2c 2d 2e 3 3 3a 3b 52-2302 52-0087 52-2561 52-0069 01-1212 01-0297 01-1119 Consult Factory Consult Factory 52-2556 01-4451 52-0263 4 4 4a 4b 5 5 68-2172 68-2173 68-0407 97-0052 99-2401 99-2402 * Specify finish DESCRIPTION *Outside Escutcheon Assembly (with keypad assy) *Outside Escutcheon only Keypad (with ribbon cable) less escutcheon Screw
KP8877/12-KP8877 & KP8878/12-KP8878 Rim Type Exit Device 3 Rim Installation Instructions for KP8800 Series NOTE: BEFORE STARTING • This device is non-handed • Door should be fitted and hung • Verify box label for size of exit device, function and hand • Install mullion in frame, if used Inside Left Hand Reverse Bevel "LHRB" Outside Step #1 Exit Hardware & Door Prep Copyright © 2006, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
2 Rim Installation Instructions for KP8800 Series (Continued) Step #2 Install Outside & Inside Trim 1. Outside Trim • Route harness through under cut of cylinder hole and out to other side of door • Mount “ET” control onto door 2. Inside Trim • Route “ET” harness along track cutout for wood doors and access hole for metal doors • Mount exit chassis carefully.
3 Rim Installation Instructions for KP8800 Series (Continued) Step #3 Apply Fire Stop Plate 1. Fire stop plate for 12-devices • Fire stop plate required in all fire rated doors (12-) • Drill (2) 1/8" diameter holes if the door is not supplied with them • Secure fire stop plate to door with (2) #8 x 1/2" self tapping screws CL OF 1-1/2" Dia. 1-1/2'' Dia. (2) 1/8" Dia.
3 Rim Installation Instructions for KP8800 Series (Continued) Step #4 Outside Keypad Escutcheon 1.
3 Rim Installation Instructions for KP8800 Series (Continued) Step #5 Inside Controller Assembly • Plug keypad connector into inside escutcheon as shown. The back plate can be removed to feed the large connector through slot into the circuit board to be assured of proper fit. If connector is not fully and properly seated on pins, unit will not function properly.
3 Rim Installation Instructions for KP8800 Series (Continued) Step #6 Rail Assembly Install rail according to installation instruction sheet A6770 Step #7 Battery Installation • Place (4) C size batteries into the compartment • Attach battery cover to inside Escutcheon and secure with #8-32 3/8" long flat head security screw #8-32 x 3/8" Long flat head screw (security screw) Inside Escutcheon Battery cover 3 2 1 6 5 4 7 9 8 # 0 Inside of door Outside of door 9 800-810-WIRE (9473) • www.
KP8977/12-KP8977 & KP8978/12-KP8978 Mortise Type Exit Device 4 Mortise Installation Instructions for KP8900 Series (Continued) NOTE: BEFORE STARTING • Check hand of door - this device is not reversible • Door should be fitted and hung • Verify box label for size of exit device, function and hand Inside Left Hand Reverse Bevel "LHRB" Outside Step #1 Exit Hardware & Door Prep Copyright © 2006, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
4 Mortise Installation Instructions for KP8900 Series (Continued) Step #2 Install Outside & Inside Trim 1. Outside Trim • Mount “ET” control onto door • Route harness through wire cutout and out to other side of door • Slide mortise lock into door and securely fasten to door with (2) flat head screws • “ET” spindle will engage into mortise lock 2. Inside Trim • Route “ET” harness along track cutout for wood doors and access hole for metal doors. • Mount exit chassis carefully.
4 Mortise Installation Instructions for KP8900 Series (Continued) Step #3 Apply Fire Stop Plate (Required for 12-) 5. Fire Stop Plate for 12- Devices • Fire stop plate required on all fire rated doors (12-) • Drill (2) 1⁄8" diameter holes if the door is not supplied with them • Secure fire stop plate to door with (2) #8 x 1/2" self tapping screws CL of 1-1/2" Dia. 1-1/2'' Dia. (2) 1/8" Dia.
4 Mortise Installation Instructions for KP8900 Series (Continued) Step #4 Outside Keypad Escutcheon 6.
4 Mortise Installation Instructions for KP8900 Series (Continued) Step #5 Inside Controller Assembly • Plug Keypad connector into inside Escutcheon as shown. The back plate can be removed to feed the large connector through slot into the circuit board to be assured of proper fit.
4 Mortise Installation Instructions for KP8900 Series (Continued) Step #6 Rail Assembly Install Rail according to installation instruction A6705 Step #7 Battery Installation • Place (4) C size batteries into the compartment • Attach battery cover to inside Escutcheon and secure with #8-32 3/8" head flat security screw. - + #8-32 x 3/8" Flat head screw (security screw) Inside Escutcheon Battery cover 3 2 1 6 5 4 9 8 7 # 0 Inside of door Outside of door 15 800-810-WIRE (9473) • www.
5 Programming Instructions The Keypad Exit Device Lock can support 100 users. Each user is assigned a User Number in addition to the code used for entry. Example: USER TYPE USER NUMBER USER CODE (2-6 DIGITS) Master Emergency Supervisor 01 02 03 1 2 3 4 2 2 2 2 2 3 0 3 0 3 0 Standard 04-97 Special Factory 10 Sec. Time Preset 98 99 2 6 5 1 3 6 8 This Keypad Exit Device Lock has 99 User Codes available for programming purposes. • The Master Code is always User “01”.
5 Programming Instructions (Continued) To Enter the Supervisory Code: 99# Master Code 50# 1# 03# Supervisory Code Supervisory Code * * * Yellow LED begins to blink slowly Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out * To Enter a User Code: 99# Supervisory or Master Code 50# 1# User Number (04-97)# User Code User Code * * * * Yellow LED begins to blink slowly Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out To Enter a Passage (Maintained Mode) Code:
5 Programming Instructions To Interrogate Transaction Log: Last 15 Entries 99# Supervisory or Master Code 70# 0# 0# Yellow LED begins to blink slowly Yellow LED blinks slowly Yellow LED begins to blink quickly (Point printer at LED as shown) Yellow LED blinks (Printing starts) * * * finished printing, press When sample transaction output * Yellow LED stops blinking Sequence number 1 is output request, Sequence numbers 2-5 are actual entries Door Number Door Number • 4 digits • Up to 9999 different do
5 Programming Instructions (Continued) Chain Programming of the KP8800 and KP8900 Series Exit Device (including 12-) When programming multiple User Numbers and Codes into the Keypad Exit Device, it is not necessary to leave and reenter the programming Mode (50) for each entry. Multiple entries may be chained together and the three different types of user codes (Standard, Passage and One time) may be mixed.
6 Programming Instructions – Français Serrure à clavier KP Exits Device Guide de programmation La serrure à clavier peut accomoder 100 utilisateurs. On doit assigner à chacun un numéro d’utilisateur, en plus de son code d’entrée..
6 Programming Instructions – Français Pour entrer un code passage (fonction maintenue): Entrer: 99# Code maître ou superviseur suivi de code d’utilisateur suivi de Code d’utilisateur suivi de * ** * 50# 2# Numéro d’utilisateur (entre 04 et 97) suivi du # et La même code devra être utilisé pour reverrouiller la serrure.
6 Programming Instructions – Français Programmation en chaîne: Pour programmer des numéros et des codes d’utilisateurs multiples, il n’est pas nésessaire de quitter le mode de prommation (50) entre chaque entrée. On peut entrer un après l’autre, en désordre, les trois différents types de codes d’utilisateurs (ordinaire, passage et une fois).. Le format à suivre est le suivant: “T” est le type de code d’usager, soit “1” pour ordinaire, “2” pour passage et “3” pour une fois.
7 Supplemental – Individual “Door” Log Sheet (KP) Lock Model: Door Name: Location: Table 2: User Programmed “Door” Log User Name User Type User Number User Programmed Code User Code Notes 23 800-810-WIRE (9473) • www.sargentlock.com • A7137B Copyright © 2006, 2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
SARGENT Manufacturing Company 100 Sargent Drive New Haven, CT 06511 USA 800-727-5477 • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets.