User Manual

Receptacle
Plug
ElectroLynx® Connector System Notes:
The system is designed to be installation friendly with
pluggable connectors from the electric hinge through
the door to the rail. The only wiring required is to the
flying leads on the pigtail harness assembly on the
frame side of the electric hinge.
IMPORTANT:
The plug and receptacle connectors are designed
to mate and lock together as shown in the figure.
Plug the connectors into each other with the locking
mechanism aligned as indicated.
Do NOT force connectors on any other way
Locking mechanism
59- Electroguard™ Exit Device - ElectroLynx Wiring Notes (Consult factory for assistance if required)
1. The ElectroLynx connector system is designed to be installation friendly with pluggable connectors from the
electric hinge through the door to the rail. The rail, raceway, electric hinge, and pigtail harness connector
terminations and wire colors all match.
2. For most applications, an 8-pin electric hinge is required.
3. A 12-pin (8 & 4-pin) electric hinge is required for all three remote alarm relay (RAR) contacts or latch bolt
monitoring (LBM) or Gang.
4. If Gang is required, a connection choice should be made depending on which rail wires are unused leading to
the 8- and 4-pin door side electric hinge. When determined, cut those wires from the door side electric hinge
connector and hard wire from the raceway to the cut electric hinge wires.
5. Plug raceway connectors into ElectroLynx hinge connectors. Hard wire to corresponding pigtail harness wires
as required.
4
Installation Instructions (Continued)
8 1-800-810-WIRE • www.sargentlock.com • A7690E
Copyright © 2013, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
04/15/13
Electroguard
®
59- Prefix 80 Series Exit Device