User Manual
RED/GREEN (GANG)
RED/YELLOW( GANG)
WHITE( REMOTE RESET)
REMOTE POS+
+COIL-
RELAY
MODULE
N.O. C
TO (-)R ETURN
TO (-)R ETURN
TO (-)R ETURN
+C OIL-
RELAY
MODULE
N.O. C
+COI L-
RELAY
MODULE
N.O. C
GANG
REMOTE
RESET
RED/GREEN (GANG)
RED/YELLOW( GANG)
WHITE( REMOTE RESET)
RED/GREEN (GANG)
RED/YELLOW( GANG)
WHITE( REMOTE RESET)
RED/GREEN (G ANG)
RED/YELLOW (GANG)
TO MOMENTARYWET
CONTACT
TO ADDITIONAL DOORS
TO (-)RET URN
1. When Electroguards are connected on a bank of doors, it is possible to have them all released simultaneously
( see wiring layout below).
2. All ganged units must share the same power supply to avoid ground loops.
3. All interconnecting equipment must be located within the same area.
4. A total of 12 doors can be ganged together when randomly distributed across 1000 feet of cable or less using
18 gauge wire.
5. Ganged doors must have their remote reset lines connected in parallel to a N. O. (normally open) dry contact.
For long wire runs (1000 ft. max) each remote reset line must be wired to a relay module (as shown) so all doors
may be reset together remotely from a momentary wet contact. Wet contact can typically be found at a panel,
remote console or switch.
Gang Mode for Banks of Doors - Optional
Gang option with Remote Reset
System Wiring Examples (Continued)