User Manual
N.O.
24VDC 1.0AMP Regulated and Filtered Power Supply
110-120 VAC
Voltage adjust
for battery
backup
HOT
NEUT
GND
123
AC F
Low voltage AC
From transformer
AC
DC
DC
Output
Plug pigtail harness
connector into 8-pin
hinge connector at
frame side of door
NOTE: This drawing shows the
BPS Series. The PM Series
has no line voltage input, fuse
or connector to power on LED
2.5 AMP polyswitch breaker
Red
Black
Unconnected
terminal
for switch
hookup
Raceway harness with 8 & 4-pin
connectors. The 4-pin connector
is not used here.
Battery Pack
Red
(+24), 2
Normally Closed Fire
Alarm Contact
(If Required)
Black
(- Return), 1
Green (EG), 4
59- 80 Series Rail with 8 &
4-pin connectors The 4-pin
connector is not used here
Note: Typical raceway location is
shown. Other locations may exist
depending on door type
8
7
6
5
4
3
2
1
Pigtail harness
assembly with
8-pin connector
Wiring Notes:
1. Rail, raceway, electric hinge and
pigtail 8-pin connector terminations
and wire colors all match.
2. Tape or cap off ends of unused pigtail
wires (not shown) to ensure that they
do not short.
3. A fire alarm tie-in is required on fire
rated openings.
4. The fire alarm contact (when
required) must be wired to drop
24VDC power to rail. In this case,
terminate fire alarm contact
between the red (+ 24VDC) wire
and supply + 24VDC output.
System Wiring Examples
Sample Wiring #1 – Basic 59- Delayed Egress with Fire Alarm and Remote Reset
During a fire alarm condition, the fire alarm contact opens which de-energizes the rail magnet and allows
immediate egress.
Line voltage
fuse (1 AMP)
Electric hinge with
8-pin connectors
Blue (DS), 6
Connector
to power on LED
9
White, RR
26 1-800-810-WIRE • www.sargentlock.com • A7690E
Copyright © 2013, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
04/15/13
Electroguard
®
59- Prefix 80 Series Exit Device