User Manual

The following are the input and output connector designations.
Harness Circuit
Connector Board Input/ Harness Function
Pin No.* Pin No. Output Wire Color
8-2 J1-1 input Red +24VDC power
8-1 J1-2 input Black -Return
8-3 J1-4 input White
8-5 J1-5 input Orange External inhibit - disarm unit from
i/s or o/s (key switch, card reader, keypad)
8-6 J1-6 input Blue Door position sensor (Door Status/Monitor)
8-4 Chassis Ground Green ESD (Earth) Ground
8-7 J1-8 output Brown Remote alarm relay (C.)
4-1 J1-9 output Violet Remote alarm relay (N.O.)
8-8 J1-10 output Yellow Remote alarm relay (N.C.)
4-2 J1-11 output Grey Latchbolt monitor relay (C.)
4-4 J1-12 output Tan Latchbolt monitor relay (N.O.)
4-3 J1-13 output Pink Latchbolt monitor relay (N.C.)
The Latchbolt monitor relay prevents the door from
being armed when latchbolt or vertical rods are
retracted.
NOTES:
1. Remote alarm relay shown in power “off” state. Power “on” relay energizes; contacts reverse state.
2. Latchbolt monitor relay shown in power “off” state. Power “on” relay energizes; contacts reverse state.
flying lead J1-16 output Red/Black Gang (N.C.)
flying lead J1-15 output Red/Yellow Gang (N.O.)
flying lead J1-14 output Red/Green Gang (C)
N.O.
N.C.
Remote Reset
N.O.
*Example: 8-2 is the 8-pin connector position #2
4-3 is the 4-pin connector position #3
Electroguard™ Wiring (Continued)
7
23 1-800-810-WIRE • www.sargentlock.com • A7690E
Copyright © 2013, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
04/15/13
Electroguard
®
59- Prefix 80 Series Exit Device