User Manual

Chassis
mounting
holes
Inside of door
Opening in
chassis for
wire
Chassis
arm
MOUNT CHASSIS
1. Feed wire and connector through chassis as shown;
mount chassis
2. Snap the ElectroLynx connectors together and
gather excess wire in the top section of the chassis.
Wire tie in place.
3. Finish installation per instruction sheet A6705
and Section 10 within this manual
Rail assembly
Truss head
screws
Rail wire &
connector
Push rail
Latchbolt
Lever
Lever arm
H. Installing 59-8900/12-59-8900 Series Mortise Lock Exit Device (continued)
IMPORTANT: Surface of door where exit
device is to be applied must be flush.
Clear away any raised projections to
allow exit device to rest on flat surface
of door.
4
Installation Instructions (Continued)
19 1-800-810-WIRE • www.sargentlock.com • A7690E