User Manual

Mounting
bracket
Top
case
Top
bolt
Top
rod
Inner
chassis
Bottom
rod
Bottom
bolt
Bottom
plate
Top bolt’s flat
Wire &
connector
Wire hole
(2) #10 x 1 1/4”
Wood screw
Wire holder
Center case
chassis
*(2) 6-32 x 3/8”
Long machine screw
Center
case
chassis
Rail wire
connector
(1) #10-24
3/4”
Machine
screws
(4) #10
Wood Screws
Rail assembly
Push rail
Chassis arm
Cover
ATTACH CHASSIS
1. Feed wire and connector through chassis as shown; mount chassis
2. Snap the ElectroLynx connectors together and gather the
excess wire in the top section of the chassis. Wire tie in place.
3. Finish installation per instruction sheet A3937 and
Section 10 within this manual
D. Installing 59-WD8600/12-59-WD8600 Concealed Vertical Rod
Exit Devices
CAUTION – BEFORE STARTING:
• Check hand of door (This device is handed and not reversible)
• Door should be fitted and hung
• Verify box label for size of exit device, function and hand
PREPARE DOOR AND INSTALL RODS INTO DOOR
Refer to Instruction sheet A3937
IMPORTANT: Surface of door where
exit device is to be applied must be
flush. Clear away any raised projec-
tions to allow exit device to rest on flat
surface of door
4
Installation Instructions (Continued)
14 1-800-810-WIRE • www.sargentlock.com • A7690E
Copyright © 2013, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
04/15/13
Electroguard
®
59- Prefix 80 Series Exit Device