User Manual
5
Factory Default Settings
Default factory presets for the 57- are as follows:
Status LEDs/Time Horn
Armed (Delayed Egress) Solid GREEN Off
Momentary Egress (Passage Delay) Flashing RED for (5) seconds Off
Disarmed Solid RED Off
Alarm Flashing RED & GREEN (15)
seconds for egress
On
Nuisance Delay (1) second On
Nuisance Audible On
Momentary Egress Time (5) seconds
Reverse LED RED (Armed)
Handing ”Top” LED (Armed) for
LHRB or RHRB
If default feature settings need to be changed, carefully slide the insert assembly
from the rail assembly to make the proper DIP switch adjustments (see Section 5
- DIP Switch Settings).
OFF
ON
For example, solid RED can be set to indicate that the rail is ”Armed” with solid
GREEN indicating that rail is ”Disarmed”.
NOTE: Use caution when
removing insert assembly
to avoid damaging the rail
harness connected to the
PCB module assembly.
Insert Assembly
S2
9 1-800-810-WIRE • www.sargentlock.com • A7743C
Copyright © 2013, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
04/15/13
57- Prefix 80 Series Exit Device