Owner`s manual
34
Adirondack Spas®
OWNER'S MANUAL
LE - HEATING MODES
Mode is changed by pressing the Warm or Cool button, then pressing the Mode button. The
heating modes "do not" control the circulation pump. It only controls the way the spas will heat
and during what time of day.
Standard Mode is programmed to maintain the desired temperature continuously,
thermostatically on a daily basis. Note that the last measured spa temperature displayed is
current only when the pump has been running for at least 2 minutes. "Std" will be displayed
momentarily when you switch into Standard Mode.
Economy Mode heats the spa to the set temperature only during your chosen economy
mode cycles, as needed. "Ecn" will display solid when temperature is not current, and will
alternate with temperature when temperature is current. You can choose 2, 4, 6 or 8 hours of
heat option during a 12 hour time frame. If you choose 2 hours on then the heat option will be
off for 10 hours. Then on for 2, then off for 10, and so on. This is not a filtration cycle but a
time frame you choose to allow the spa to heat if needed.
Sleep Mode heatsthespawithin20°F/10°Cofthesettemperatureonlyduringfiltercycles.
"SLP" will display solid when temperature is not current, and will alternate with temperature
when temperature is current. This cycle is designed when the spa will not be used for long periods
of time. Water sanitizing and balance will still be necessary even if the spa is not being used.
Note: The last measured spa temperature displayed is current only when the pump has been
running for at least 2 minutes.
LE - FILTER CYCLE MODES
Adirondack Spas® has designed its continuous circulation pump system to operate without
manual programming. The continuous circulation pump operates unless interrupted by a system
diagnostic or automated program, or by a power failure. With the continuous circulation system,
manual filter cycles do not apply. The spa is designed to continuously circulate the water.
Freeze Protection
Ifthetemperaturesensorsdetectadroptobelow44°F/6.7°Cwithintheheater,thepumpswill
automatically activate to provide freeze protection. The equipment stays on until 4 minutes after
thesensorsdetectthatthespatemperaturehasrisento45°F/7.2°Corhigher.
Summer Set Mode
Your spa is equipped with this feature to prevent heat build up. Summer Set Mode is activated
whenthewatertemperatureexceedsthesettemperatureby3°F.WhentheSummerSetModeis
activated it will suspend the filter cycle for 30 minutes, then Pump 1 will run on low speed for 2
minutes. It will continue this way until the water temperature returns to the set temperature.
Automated Purge Cycle
Every 12 hours the Jet Pump(s) will engage. Pump 1 on low speed, and on selected models
Pumps 2 and Pumps 3 on high speed for a duration of 5 minutes. This process purges the jet
plumbing lines twice daily, making sure water in the plumbing lines is moved out into the spas
main body of water.