Owner`s manual
19
Adirondack Spas®
OWNER'S MANUAL
INSTALLATION INSTRUCTIONS:
The following instructions are for the conversion of the Adirondack Spas® 110V/220V control
pack from a 220 Volt application to a 110 Volt application.
Due to the risk of equipment damage or fire, use only approved pressure-type wire
splicing lugs or connectors suitable for the size and type of wiring used.
Before servicing the spa, make sure all power to the spa is disconnected. Follow these instructions
for a successful electrical installation.
1. Unscrew the screws on the front access panel.
2. Carefullypullaccesspaneltowardyou(awayfromspa)andpullupward.Setaccess
panel aside.
3. Locate the spa power pack. Loosen the screws on the front of the control box. Remove the
control box cover and the terminal block will be exposed.
4. Route the GFCI power cord through the vent hole in the base of the equipment
compartment and out from under the corner of the spa.
Note: 110 Volt installations require a 60Hz, single phase, two-wire electrical service plus
ground(Line1,NeutralandGround)andmustbeconnectedusingaminimumsupply
conductor ampacity of 20 Amps and a minimum GFCI circuit breaker size of 20 Amps.
5. Input the GFCI power cord to the terminal block inside the spa pack.
6. Connect the 8 AWG WHITE wire, from the power cord, to the WHITE "NEU" terminal
on TB1.
7. Connect the 8 AWG BLACK wire, from the power cord, to the BLACK "HOT" terminal on
TB1.
8. Connect the 8 AWG GREEN wire, from the power cord, to the GREEN "GROUND"
location on the "BONDING LUGS" terminal.
9. Connectjumperwire(jumperwiretapedtothebackofthespapack)toJ11andJ32.Red
AC to White AC
10. Move dip switch #10 to the ON position. Special amperage rule "ON"
11. Replace the control box cover and securely tighten the fastening screws. Close and secure the
equipment compartment panel.
Note: Please review the back of the spa power pack cover, in the equipment bay, for a complete
spa wiring diagram.
!
!