Installation manual
The Sapling Company, Inc.
1633 Republic Road
Huntingdon Valley, PA 19006
215.322.6063 P.
215.322.8498 F.
www.sapling-inc.com
21
Option 50 - Entering Diagnostic Mode
Press the bottom button to scroll between “E - d”. Setting the option
to “E” will enable the option and will enter diagnostic mode. Setting
the option to “d” will disable the option and upon depressing the top
button, the clock will return to the time.
Option 51 - Sends Diagnostic to Slave Clock
Pressing the bottom button will scroll from “1-5 and 9”.
01 - Protocol Verification
02 - Comprehensive Test
03 - Manufacturer’s Default
04 - Combination of 02 & 03 (button must be pressed on SAM)
05 - Combination of 02 & 03 (no need to press button on SAM)
09 - Overrides the Previous Diagnostic and Goes Back to the Time
Option 52 - Set Duration (in minutes) that the Results of the Diagnostic
will be Viewable on the Clock
Pressing the bottom button will scroll from “00-60”. Pressing the top
button will go back to the displayed time.
User Level Programming