Installation manual

The Sapling Company, Inc.
1633 Republic Road
Huntingdon Valley, PA 19006
215.322.6063 P.
215.322.8498 F.
www.sapling-inc.com
16
Option 3 - Set Day:
Use the bottom button to scroll between “01-31”.
Option 10 - Technical Mode:
If technical mode is desired, press the bottom button until “08” is
reached. Setting option 10 to “08” will allow the user access to options
11-13 when the top button is pressed. Any other value will go directly
to option “20” when the top button is pressed.
Option 11 - RS485 Data Rate:
Press the bottom button to scroll between “01-12”.
01 - Data is transmitted every second 07 - Data is transmitted every 2 minutes
02 - Data is transmitted every 5 seconds 08 - Data is transmitted every 5 minutes
03 - Data is transmitted every 10 seconds 09 - Data is transmitted every 10 minutes
04 - Data is transmitted every 15 seconds 10 - Data is transmitted every 15 minutes
05 - Data is transmitted every 30 seconds 11 - Data is transmitted every 30 minutes
06 - Data is transmitted every minute 12 - Data is transmitted every hour
Option 12 - Daylight Savings Time:
Press the bottom button to scroll between “d”, “1”, or “2”.
“d” will disable this option.
“1” will enable daylight savings pre 2007.
“2” will enable daylight savings post 2007.
Option 13 - 12/24 Hour Mode:
Press the bottom button to scroll between “12” and “24”.
User Level Programming