Option 11 - RS485 Data Rate:
This options allows a user to set the RS485 data rate. The RS485 data
rate is the rate at which data (for example the time and/or date) is sent
to the clock.
Press the bottom button to scroll between “00-12.” See Table 1 for
RS485 Data Rate settings.
Once the RS485 Data Rate is selected, press the top button to continue
on to Option 13.
Option 13 - Loss of Communication Alert:
This option allows the user to enable or disable the Loss of
Communication Alert on the digital clock display. The digital clock will
signal a loss of communication with the master clock by blinking the
colons on the display. Press the bottom button to scroll between “E - d.”
Enabling this option (E) will allow the user to proceed to option 14 to
configure the loss of communication alert. Disabling this option (d) will
keep the colons solid and not show a loss of communication. Disabling
should be used when the clock is in independent mode.
If a user has chosen to enable (E) the Loss of Communication Alert, when
the top button is pressed, the user will be taken to option 14. If a user
chooses to disable (d) the Loss of Communication Alert, when the top
button is pressed, the user will be taken to option 15.
Option 14 - Set the Loss of Communication Alert:
This option will allow the user to choose at what point the colons will
blink after communication with the master clock is lost. Press the bottom
button to scroll between “01-10.”
See Table 2 below for settings.
Once the Loss of Communication Alert setting is selected, press the top
button to continue on to Option 15.
14 06
Table 2
01 - Data is lost after 5 minutes 06 - Data is lost after 60 minutes
02 - Data is lost after 10 minutes 07 - Data is lost after 90 minutes
03 - Data is lost after 15 minutes 08 - Data is lost after 120 minutes
04 - Data is lost after 30 minutes 09 - Data is lost after 180 minutes
05 - Data is lost after 45 minutes 10 - Data is lost after 240 minutes
13 E
OPTION
SETTING
00 - Data is off 07 - Data is transmitted every 2 minutes
01 - Data is transmitted every second 08 - Data is transmitted every 5 minutes
02 - Data is transmitted every 5 seconds 09 - Data is transmitted every 10 minutes
03 - Data is transmitted every 10 seconds 10 - Data is transmitted every 15 minutes
04 - Data is transmitted every 15 seconds 11 - Data is transmitted every 30 minutes
05 - Data is transmitted every 30 seconds 12 - Data is transmitted every hour
06 - Data is transmitted every minute
Table 1
11 01
Programming