Temperature Sensor Wiring (Optional)
If you ordered a Temperature Sensor with your SBD 3000 clock, it
must be connected to a terminal on the Clock.
Connecting The Temperature Sensor
Temperature Sensor
Sensor Cable
(IMPORTANT: Detach clock from power source before installing
new circuitry. DO NOT add new circuitry while the clock is operating)
Attach the end of the Temperature Sensor Wire to the circuit board in
the following manner:
Data from the temperature sensor will be sent to your clock when
the clock is powered on. For more information on how to make the
SBD 3000 display temperature, please see the section labeled “Web
Interface - Display Settings”.
The Sensor Cable is 6 feet (1.83 meters) long, and so the sensor
should be positioned within 6 feet of the clock. The cable is
unshielded, 4 conductor, 22AWG (.33mm²). If longer than 6 feet is
required, the wire would have to be terminated in an electrical box,
and the longer wire would have to be provided by the customer.
1
2
3
4
5
5) No connection
4) White
3) Black
2) Green
1) Red