Wiring Information
Wiring and Jumper Settings (3300 Series)
**Jumper Position
JP 1
JP 4
JP 5
JP 6
JP 2
JP 3
Power Settings
1
4
5
2
3
24VAC @ 0.35A (ORG)
120VAC or 240VAC @ 0.1A (BLK)
No Connection
120VAC or 240VAC @ 0.1A (WHT)
24VAC @ 0.35A (YEL)
Elapsed Timer
5
2
1
4
3
No Connection
TXD (Blue&Blue/White)
Common (Green&Green/White)
RXD (Orange&Orange/White)
3.3V@0.1A (Brown&Brown/White)
P1 - Sync Inputs
P2 - User Inputs
1
2 3
4 5
6 7 8 9
1
2 3
4 5
6 7 8 9
AC / DC Com
120VAC or 240VAC Sync
24VAC Sync
Dukane Reset
Dukane Pulse
Dry Contact
3.3VDC@20ma
Common
Common
User Input 4
User Input 3
User Input 2
User Input 1
12VDC@40ma
Each User Input is
a Contact Closure
P3 - Relay Output
4
3
2
1
*Relay 1 N.O.
*Relay 2 N.O.
*Contact Rating
0.3A @ 120VAC
0.5A @ 24 VAC
Note: When setting up the jumpers, Pin 1 & Pin 2 must be jumpered together OR
Pin 2 & Pin 3 must be jumpered together. Below are the Jumper Positions and what
function each corresponds with.
Pin
1 2 3
Jumper Position Pin 1 & Pin 2 Pin 2 & Pin 3
JP 1 12 Hour Time 24 Hour Time
JP 2 Bright Dim
JP 3 Time Display Only Alternating Date/Time Display
JP 4 Normal Configuration
JP 5 Real Time Clock 60Hz
JP 6 Sync RS485 Select
Cat 5
Cable
Wiring Information
P7 - RS485
1 2 3 4
Input A
Input B
Output A
Output B
Note: Pin 1 will always be
the square pad.