13) Mount the zone clock pole and attached housings to the bases by hanging the upper edge
of the pole on the upper hooks of the base. Then, using the flathead screwdriver, turn the inner
screw counterclockwise to activate the lower locking mechanism.
Test the pole to confirm that the locking mechanism has fully engaged. The pole should be able
to slide side to side while attached to the base, but a user should not be able to lift the pole
off of the base. FAILURE TO FULLY ENGAGE THE LOCKING MECHANISM MAY RESULT IN
INJURY.
Open
Locked
12) Skip this step if your clock is battery-powered or uses Power over Ethernet.
Attach the grounding screw to the hole in the zone clock pole. Leave some space between the
head of the screw and the pole so that the grounding cable can be attached later.