User's Manual
VS-600 Resident Unit Manual B-5
Pendant low battery: The dial string the unit will call when a pendant’s battery is low.
Wireless Pull Cord low battery: The dial string the unit will call when a wireless pull cord
unit’s battery is low.
Wireless Pull Cord no communication: The dial string the unit will call when it loses contact
with the wireless pull cord.
Repeat interval (hours): The resident unit will redial the dial string after a certain number of
hours as long as the triggering condition is present.
For an explanation of a dial string example, refer to Creating Dial Strings, section B.5.
B.3.1.3 Misc. Tab
The Misc. tab contains dial string settings not covered in the other tabs.
Misc. Tab
“Cancel” DTMF string: The dial string the resident unit calls when the cancel button is pressed.
For an explanation of a dial string example, refer to Creating Dial Strings, section
B.5.
B.3.2 Saving Programming Information to a File
You can save the current settings from the Options and Prog./Config. tabs to a file. This is
useful for quickly programming multiple resident units with the same settings.
To save the current configuration settings to a file, click Save options and config to file, type a
file name for your configuration file, then click Save.
To load configuration settings from a file, click Load options and config from file, select your
configuration file, then click Open.
Click Get beside Load options and config from file to download the settings from the resident
unit.