Page 42 /
50
7.11 VOLTAGE DIPS AND INTERRUPTION
LIMIT
Please refer to EN 61000-4-11.
TEST CONFIGURATION
TEST PROCEDURE
Please refer to ETSI EN 301 489-1 Clause 9.7.2 and EN 61000-4-11 for the
measurement methods.
TEST RESULTS
Temperature
26
o
C
Humidity
46% RH
Pressure
1029 mbar
Tested By
Vision Chang
Required Passing
Performance
Transient Phenomena:
>95% reduction 10ms & >95% reduction 20ms & 30% reduction 500ms
By User Recoverable Phenomena: >95% reduction 5000ms
Test Power: 230Vac, 50Hz
Voltage
( Reduction)
Duration
(ms)
Criteria Test Result
>95 0.5&1 A B C D
PASS
30 25 A B C D
PASS
>95 250 A B C D
PASS
Dips/Interruption
and Variations
Simulator
Controller Computer
EUT
&
Support Units
0.8m
To AC
Source