7.9 AC MAINS SURGE
LIMIT
Please refer to EN 61000-4-5.
TEST CONFIGURATION
TEST PROCEDURE
Please refer to ETSI EN 301 489-1 Clause 9.8.2 and EN 61000-4-5 for the measurement
methods.
TEST RESULTS
Temperature
26
o
C
Humidity
46 % RH
Pressure
1029mbar
Tested By
Vision Chang
Required Passing Performance
Transient Phenomena
Test Point Polarity
Test Level
(kV)
Criteria Result
L –N
+/- 1kV A B C D
PASS
Phase shifting Repetition Rate
Waveform
parameter
Coupling Rate
Combine Wave
1.2μs/50μs
8μs /20μs
5 times
0°、90°、180°、270°
30 sec
Impedance
2 Ω / 12 Ω
Each Angle
and Polarity
Surge
Immunity Test
System
Controller Computer
EUT
&
Support Units
0.8m
To A C
Source