User`s manual

Reference No T11112830801-RE
Report No T11112830801-RE
Page 21 /
50
7.2 AC MAINS LINE CONDUCTED EMISSION
LIMIT
Please refer to ETSI EN 301 489-1 Clause 8.4.3, Table 8 and EN 55022 Clause 5, Table
2, Class B.
TEST CONFIGURATION
TEST PROCEDURE
Please refer to ETSI EN 301 489-1 Clause 8.4.3 and EN 55022 Clause 5 for the
measurement methods.
TEST RESULTS
No non-compliance noted.
EUT
LISN
EMI receiver
Reference ground plane
Vert. reference plane
40cm
80cm