Compliance Certification Services Inc.
Report No:T11112830801-LV
National Differences
Clause Requirement − Test
Result – Remark Verdict
Page 60 of 72
conditions specified.
4.2.8.1 Enclosures around CRTs with a face
diameter of 160 mm or more are required to
reduce the risk of injury due to the implosion
of the CRT.
No CRTs.
N
4.2.11 For equipment intended for mounting on
racks and provided with slide/rails allowing
the equipment to slide away from the rack for
installation, service and maintenance,
additional construction, performance and
marking requirements are applicable to
determine the adequacy of the slide/rails.
No such device.
N
4.3.2 Equipment with handles is required to comply
with special loading tests.
No handles.
N
5.1.8.3 Equipment intended to receive
telecommunication ringing signals is required
to comply with a special touch current
measurement tests.
No TNV circuits.
N
5.3.7 Internal (e.g., card cage) SELV circuit
connectors and printed wiring board
connectors that are accessible to the operator
and that deliver power are to be overloaded.
During abnormal operating testing, if a circuit
is interrupted by the opening of a component,
the test shall be repeated twice (three tests
total) using new components as necessary.
N
6.4 Equipment intended for connection to
telecommunication network outside plant
cable is required to be protected against
overvoltage from power line crosses in
accordance with 6.4 and Annex NAC.
No TNV circuits.
N
M.2 Continuous ringing signals up to 16 mA only
are permitted if the equipment is subjected to
special installation and performance
restrictions.
No TNV circuits.
N
Annex
NAD
Equipment connected to a telecommunication
and cable distribution networks and supplied
with an earphone intended to be held against,
or in the ear is required to comply with special
acoustic pressure requirements.
No TNV circuits.
N
Annex
NAF
Document (paper) shredders likely to be used
in a home or home office (Pluggable
Equipment Type A plug configuration) are
required to comply with additional
requirements, including markings/instructions,
protection against inadvertent reactivation of
a safety interlock, disconnection from the
mains supply (via provision of an isolating
switch), and protection against operator
access (accessibility determined via new
accessibility probe & probe/wedge).
N