Compliance Certification Services Inc.
Report NoT11112830801-LV
National Differences
Clause Requirement Test
Result – Remark Verdict
Page 58 of 72
3.2.3 Permanent connection of equipment to the
mains supply by a power supply cord is not
permitted, except for certain equipment, such
as ATMs.
Class III equipment.
N
3.2.5 Power supply cords are required to be no
longer than 4.5 m in length and minimum
length shall be 1.5 m. Flexible power supply
cords are required to be compatible with
Article 400 of the NEC.
No such cord provided.
N
3.2.9 Permanently connected equipment must
have a suitable wiring compartment and wire
bending space.
N
3.3.3 Wire binding screw terminal are not permitted
to attach connectors larger than 10 AWG (5.3
mm²).
No such screws provided.
N
3.3.4 Terminals for permanent wiring, including
protective earthing terminals, must be
suitable for U.S wire gauge sizes, rated 125
percent of the equipment rating, and be
specially marked when specified (1.7.7)
No such terminals provided.
N
3.4.2 Motor control devices are required for cord-
connected equipment with a motor if the
equipment is rated more than 12 A, or if the
motor has a nominal voltage rating greater
than 120 V, or is rated more than 1/3 hp
(locked rotor current over 43 A)
No motor.
N
3.4.8 Vertically mounted disconnect switches and
circuit breakers are required to have the “on”
position indicated by the handle in the up
position.
No such devices incorporated.
N
3.4.11 For computer-room applications, equipment
with battery systems capable of supplying
750 VA for five minutes are required to have
a battery disconnect means that may be
connected to the computer room remote
power-off circuit.
Not such application.
N
4.3.12 The max. quantity of flammable liquid stored
in equipment per ANSI/NFPA 30.
No flammable liquid.
N
4.3.13.5 Equipment with lasers is required to meet the
Code of Federal Regulations 21 CFR 1040.
No lasers.
N
4.7 For computer room applications, automated
information storage systems with combustible
media greater than 0.76 m³ (27 cu ft) are
required to have a provision for connection of
either automatic sprinklers or a gaseous
agent extinguishing system with an extended
discharge.
Not such application.
N
4.7.3.1 For computer room applications, enclosures
with combustible material measuring greater
tha 0.9 m
2
(10 sq ft) or a single dimension
greater than 1.8 m (6ft) are required to have a
flame spread rating of 50 or less. For other
applications, enclosures with the same
dimensions require a flame spread rating of
200 or less.
Not such application.
N