National Differences
Clause Requirement − Test
Result – Remark Verdict
Page 54 of 72
750 VA for five minutes are required to have
a battery disconnect means that may be
connected to the computer room remote
poweroff circuit.
4.3.12 The maximum quantity of flammable liquid
stored in equipment is required to comply
with NFPA 30.
No flammable liquid.
N
4.3.13.5 Equipment with lasers is required to meet the
Canadian Radiation Emitting Devices Act,
REDR C1370 and/or Code of Federal
Regulations 21 CFR 1040, as applicable.
No laser provided.
N
4.7 For computer room applications, automated
information storage systems with combustible
media greater than 0.76 m
3 (27 cu ft) are
required to have a provision for connection of
either automatic sprinklers or a gaseous
agent extinguishing system with an extended
discharge.
Not such application.
N
4.7.3.1 For computer room applications, enclosures
with combustible material measuring greater
than 0.9 m
2 (10 sq ft) or a single dimension
greater than 1.8 m (6 ft) are required to have
a flame spread rating of 50 or less. For other
applications, enclosures with the same
dimensions require a flame spread rating of
200 or less.
Not such application.
N
Annex H Equipment that produces ionizing radiation is
required to comply with the Canadian
Radiation Emitting Devices Act, REDR C1370
and/or Code of Federal Regulations, 21 CFR
1020, as applicable.
No CRTs.
N
OTHER DIFFERENCES
1.5.1 Some components and materials associated
with the risk of fire, electric shock, or personal
injury are required to have component or
material ratings in accordance with the
applicable national (Canadian and/or U.S.)
component or material standard
requirements. These components include:
attachment plugs, battery packs
(rechargeable type, used with transportable
equipment), cathode ray tubes, circuit
breakers, communication circuit accessories,
connectors (used for current interruption of
nonLPS circuits), cord sets and power supply
cords, direct plugin equipment, enclosures
(outdoor), flexible cords and cables, fuses
(branch circuit), fuseholders, groundfault
current interrupters, industrial control
equipment, insulating tape, interconnecting
cables, lampholders, limit controls, printed
wiring, protectors for communications circuits,
receptacles, solid state controls,
supplementary protectors, switches (including
interlock switches), thermal cutoffs,
Complied. Components are UL or
CSA approved, see component list
1.5.1.
P