User`s manual

Compliance Certification Services Inc.
Report NoT11112830801-LV
National Differences
Clause Requirement Test
Result – Remark Verdict
Page 53 of 72
distribution units) if the supply branch circuit
protection is not suitable. Power distribution
transformers distributing power at 100 volts or
more, and rated 10 kVA or more, require
special transformer overcurrent protection.
3.2 Wiring methods (terminals, leads, etc.) used
for the connection of the equipment to the
mains shall be in accordance with the
NEC/CEC.
Class III equipment.
N
3.2.1 Power supply cords are required to have
attachment plugs rated not less than 125
percent of the rated current of the equipment.
No supply cord provided.
N
3.2.1.2 Equipment connected to a centralized d.c.
power system, and having one pole of the DC
mains input terminal connected to the main
protective earthing terminal in the equipment,
is required to comply with special earthing,
wiring, marking and installation instruction
requirements.
Class III equipment.
N
3.2.3 Permanent connection of equipment to the
mains supply by a power supply cord is not
permitted, except for certain equipment, such
as ATMs.
Class III equipment.
N
3.2.5 Power supply cords are required to be no
longer than 4.5 m in length. Flexible power
supply cords are required to be compatible
with Tables 11 and 12 of the CEC and Article
400 of the NEC.
No supply cord provided.
N
3.2.9 Permanently connected equipment is
required to have a suitable wiring
compartment and wire bending space.
Class III equipment.
N
3.3 Wiring terminals and associated spacings for
field wiring connections shall comply with
CSA C22.2 No. 0.
No such terminals provided.
N
3.3.3 Wire binding screws are not permitted to
attach conductors larger than 10 AWG (5.3
mm
2).
No such screws provided.
N
3.3.4 Terminals for permanent wiring, including
protective earthing terminals, are required to
be suitable for Canadian/US wire gauge
sizes, rated 125 percent of the equipment
rating, and be specially marked when
specified (1.7.7).
No such terminals provided.
N
3.4.2 Motor control devices are required for cord-
connected equipment with a motor if the
equipment is rated more than 12 A, or if the
motor has a nominal voltage rating greater
than 120 V, or is rated more than 1/3 hp
(locked rotor current over 43 A).
No such device.
N
3.4.8 Vertically-mounted disconnect switches and
circuit breakers are required to have the "on"
position indicated by the handle in the up
position.
No such device.
N
3.4.11 For computer room applications, equipment
with battery systems capable of supplying
Not such application.
N