User`s manual
Compliance Certification Services Inc.
Report No:T11112830801-LV
National Differences
Clause Requirement − Test
Result – Remark Verdict
Page 47 of 72
FINLAND NATIONAL DIFFERENCES
(EN 60950-1:2006/A11:2009/A1:2010/A12:2011)
P
1.5.7.1 In Finland resistors bridging BASIC
INSULATION in CLASS I PLUGGABLE
EQUIPMENT TYPE A must comply with the
requirements in 1.5.7.1. In addition when a
single resistor is used, the resistor must
withstand the resistor test in 1.5.7.2.
Class III equipment.
N
1.5.9.4 The third dashed sentence is applicable only
to equipment as defined in 6.1.2.2 of this
annex.
No such construction.
N
1.7.2.1 CLASS I PLUGGABLE EQUIPMENT TYPE A
intended for connection to other equipment or
a network shall, if safety relies on connection
to protective earth or if surge suppressors are
connected between the network terminals
and accessible parts, have a marking stating
that the equipment must be connected to an
earthed mains socket-outlet.
The marking text in the applicable countries
shall be as follows:
"Laite on liitettävä
suojamaadoituskoskettimilla varustettuun
pistorasiaan"
Class III equipment.
N
2.3.2 There are additional requirements for the
insulation. See 6.1.2.1 and 6.1.2.2 of this
annex.
No TNV.
N
2.10.5.13 There are additional requirements for the
insulation, see 6.1.2.1 and 6.1.2.2 of this
annex.
No TNV.
N
5.1.7.1 TOUCH CURRENT measurement results
exceeding 3,5 mA r.m.s. are permitted only
for the following equipment:
• STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
- is intended to be used in a
RESTRICTED ACCESS
LOCATION where equipment
bonding has been applied, for
example, in a telecommunication
centre; and –
- has provision for a permanently
connected PROTECTIVE
EARTHING CONDUCTOR; and
- is provided with instructions for the
installation of that conductor by a
SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
• STATIONARY PERMANENTLY
CONNECTED EQUIPMENT.
Class III equipment.
N