Compliance Certification Services Inc.
Report No:T11112830801-LV
National Differences
Clause Requirement − Test
Result – Remark Verdict
Page 44 of 72
equipment with a rated current over 10 A and
up to and including 13 A.
3.3.4 In the United Kingdom, the range of
conductor sizes of flexible cords to be
accepted by terminals for equipment with a
RATED CURRENT of over 10 A up to and
including 13 A is:
• 1,25 mm2 to 1,5 mm2 nominal cross-
sectional area.
N
4.3.6 In the United Kingdom, the torque test is
performed using a socket outlet complying
with BS 1363 part 1:1995, including
Amendment 1:1997 and Amendment 2:2003
and the plug part of DIRECT PLUG-IN
EQUIPMENT shall be assessed to BS 1363:
Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12,
12.13, 12.16 and 12.17, except that the test
of 12.17 is performed at not less than 125 °C.
Where the metal earth pin is replaced by an
Insulated Shutter Opening Device (ISOD), the
requirements of clauses 22.2 and 23 also
apply.
N
4.3.6 In Ireland, DIRECT PLUG-IN EQUIPMENT is
known as plug similar devices. Such devices
shall comply with Statutory Instrument
526:1997 -National Standards Authority of
Ireland (Section 28) (Electrical plugs, plug
similar devices and sockets for domestic use)
Regulations, 1997.
N
5.1.7.1 In Finland, Norway and Sweden TOUCH
CURRENT measurement results exceeding
3,5 mA r.m.s. are permitted only for the
following equipment:
• STATIONARY PLUGGABLE EQUIPMENT
TYPE A that
- is intended to be used in a
RESTRICTED ACCESS
LOCATION where equipment
bonding has been applied, for
example, in a telecommunication
centre; and –
- has provision for a permanently
connected PROTECTIVE
EARTHING CONDUCTOR; and
- is provided with instructions for the
installation of that conductor by a
SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT
TYPE B;
• STATIONARY PERMANENTLY
CONNECTED EQUIPMENT.
Class III equipment.
N
6.1.2.1
(A1:2010)
In Finland, Norway and Sweden, add the
following text between the first and second
paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least
No TNV.
N