User`s manual
Compliance Certification Services Inc.
Report No:T11112830801-LV
National Differences
Clause Requirement − Test
Result – Remark Verdict
Page 43 of 72
protection against indirect contact is required
according to the wiring rules shall be provided
with a plug in accordance with standard sheet
DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT
exceeding 13 A is provided with a supply cord
with a plug, this plug shall be in accordance
with the Heavy Current Regulations, Section
107-2-D1 or EN 60309-2.
3.2.1.1 In Spain, supply cords of single-phase
equipment having a rated current not
exceeding 10 A shall be provided with a plug
according to UNE 20315:1994.
Supply cords of single-phase equipment
having a rated current not exceeding 2,5 A
shall be provided with a plug according to
UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are
intended to be used in locations where
protection against indirect contact is required
according to the wiring rules, shall be
provided with a plug in accordance with
standard UNE 20315:1994.
If poly-phase equipment is provided with a
supply cord with a plug, this plug shall be in
accordance with UNE-EN 60309-2.
N
3.2.1.1 In the United Kingdom, apparatus which is
fitted with a flexible cable or cord and is
designed to be connected to a mains socket
conforming to BS 1363 by means of that
flexible cable or cord and plug, shall be fitted
with a ‘standard plug’ in accordance with
Statutory Instrument 1768:1994-The Plugs
and Sockets etc.
(Safety) Regulations 1994, unless exempted
by those regulations.
NOTE ‘Standard plug’ is defined in SI
1768:1994 and essentially means an
approved plug conforming to BS 1363 or an
approved conversion plug.
N
3.2.1.1 In Ireland, apparatus which is fitted with a
flexible cable or cord and is designed to be
connected to a mains socket conforming to
I.S. 411 by means of that flexible cable or
cord and plug, shall be fitted with a 13 A plug
in accordance with Statutory Instrument
525:1997 -National Standards Authority of
Ireland (section 28) (13 A Plugs and
Conversion Adaptors for Domestic Use)
Regulations 1997.
N
3.2.4 In Switzerland, for requirements see 3.2.1.1
of this annex.
N
3.2.5.1 In the United Kingdom, a power supply cord
with conductor of 1,25 mm2 is allowed for
N