User`s manual

Compliance Certification Services Inc.
Report NoT11112830801-LV
National Differences
Clause Requirement Test
Result – Remark Verdict
Page 39 of 72
equipment or as parts of the building
installation, subject to the following, a), b) and
c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as parts
of the equipment;
b) for components in series with the mains
input to the equipment such as the supply
cord, appliance coupler, r.f.i. filter and switch,
shortcircuit and earth fault protection may be
provided by protective devices in the building
installation;
c) it is permitted for PLUGGABLE
EQUIPMENT TYPE B or PERMANENTLY
CONNECTED EQUIPMENT, to rely on
dedicated overcurrent and shortcircuit
protection in the building installation, provided
that the means of protection, e.g. fuses or
circuit breakers, is fully specified in the
installation instructions. If reliance is placed
on protection in the building installation, the
installation instructions shall so state, except
that for PLUGGABLE EQUIPMENT TYPE A
the building installation shall be regarded as
providing protection in accordance with the
rating of the wall socket outlet.
2.7.2 This subclause has been declared ‘void’.
N
3.2.3 Delete the NOTE in Table 3A, and delete also
in this table the conduit sizes in parentheses.
Deleted.
N
3.2.5.1 Replace
“60245 IEC 53” by “H05 RR-F” ;
“60227 IEC 52” by “H03 VV-F or H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or H05 VVH2-F2”.
In Table 3B, replace the first four lines by the
following:
| Up to and including 6
| 0,75
a)
|
| Over 6 up to and including 10
| (0,75)
b)
1,0 |
| Over 10 up to and including 16
| (1,0)
c)
1,5 |
In the conditions applicable to Table 3B
delete the words “in some countries” in
condition
a)
.
In NOTE 1, applicable to Table 3B, delete the
second sentence.
Replaced.
N
3.3.4 In Table 3D, delete the fourth line: conductor
sizes for 10 to 13 A, and replace with the
following:
| Over 10 up to and including 16
| 1,5 to 2,5 | 1,5 to 4 |
Delete the fifth line: conductor sizes for 13 to
16 A.
Deleted.
N