User`s manual

Compliance Certification Services Inc.
Report NoT11112830801-LV
National Differences
Clause Requirement Test
Result – Remark Verdict
Page 38 of 72
example built-in volume level control).
NOTE The values of 94 dBA – 75 mV correspond with
85dBA – 27 mV and 100 dBA – 150 mV.
Zx.4.2 Wired listening devices with digital
input
With any playing device playing the fixed
“programme simulation noise” described in
EN 50332-1 (and respecting the digital
interface standards, where a digital interface
standard exists that specifies the equivalent
acoustic level), the acoustic output LAeq,T of
the listening device shall be 100 dBA.
This requirement is applicable in any mode
where the headphones can operate, including
any available setting (for example built-in
volume level control, additional sound feature
like equalization, etc.).
NOTE An example of a wired listening device with digital
input is a USB headphone.
N
Zx.4.3 Wireless listening devices
In wireless mode :
- with any playing and transmitting device
playing the fixed programme simulation
noise described in EN 50332-1; and
- respecting the wireless transmission
standards, where an air interface standard
exists that specifies the equivalent acoustic
level; and
- with volume and sound settings in the
listening device (for example built-in volume
level control, additional sound feature like
equalization, etc.) set to the combination of
positions that maximize the measured
acoustic output for the above-mentioned
programme simulation noise, the acoustic
output L
Aeq,T
of the listening device shall be
100 dBA.
NOTE An example of a wireless listening device is a
Bluetooth headphone.
N
Zx.5 Measurement methods
Measurements shall be made in accordance
with EN 50332-1 or EN 50332-2 as
applicable. Unless stated otherwise, the time
interval T shall be 30 s.
NOTE Test method for wireless equipment provided
without listening device should be defined. k
N
2.7.1 Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-
circuits and earth faults in PRIMARY
CIRCUITS, protective devices shall be
included either as integral parts of the
Replaced.
P